The Moxa MGate 5121-T is a 1-port industrial Ethernet gateway designed for converting CANopen or J1939 protocols to Modbus TCP. This device facilitates seamless communication between CAN-based devices and Modbus TCP networks, commonly found in industrial automation and control systems. It supports a wide operating temperature range of -40 to 75°C, making it suitable for harsh industrial environments.
2. Émbaran Kasalametan
Please read and understand all safety instructions before installing or operating the MGate 5121-T gateway. Failure to follow these instructions may result in equipment damage, personal injury, or system malfunction.
- Pastikeun kakuatan dipegatkeun saméméh instalasi atawa perawatan.
- Install the device in a well-ventilated area, away from excessive heat, moisture, or corrosive substances.
- Anggo alat sareng alat pelindung diri anu pas nalika pamasangan.
- Sadaya kabel kedah saluyu sareng kode listrik lokal sareng nasional.
- Ngan tanaga anu mumpuni kedah ngalaksanakeun pamasangan sareng perawatan.
3. Eusi Paket
Pariksa yén pakét anjeun ngandung barang-barang ieu:
- MGate 5121-T Gateway Unit
- Guide Instalasi Gancang
- Kartu Garansi
- (Optional) DIN-rail mounting kit
If any of these items are missing or damaged, please contact your sales representative for assistance.
4. Produk Langkungview
4.1 Fitur konci
- Converts CANopen/J1939 to Modbus TCP
- 1 CAN port, 1 Ethernet port
- Wide operating temperature: -40 to 75°C
- Redundant power inputs
- Webkonfigurasi -based
- DIN-rel dipasang
4.2 Hardware Katerangan
The MGate 5121-T features a robust metal casing designed for industrial environments. It includes LED indicators for power, status, and communication activity, allowing for quick visual diagnostics. The device provides screw terminals for power input and CAN bus connections, and an RJ45 port for Ethernet connectivity.
Note: No suitable product images were provided in the input data for embedding. If available, images showing the front panel, side view with ports, and LED indicators would be placed here with descriptive alt-text.
5. Setélan
5.1 Pamasangan
The MGate 5121-T can be mounted on a standard 35mm DIN-rail or wall-mounted using the optional wall-mounting kit.
- DIN-rail Pamasangan: Attach the DIN-rail clip to the back of the device. Hook the top of the clip onto the DIN-rail and push the bottom until it snaps into place.
- Pamasangan témbok: Secure the wall-mounting plates (if applicable) to the device using screws. Mark and drill holes on the wall, then attach the device using appropriate screws.
5.2 Sambungan Daya
The gateway supports redundant DC power inputs. Connect a 12-48 VDC power supply to the terminal block labeled "PWR1" and "PWR2". Ensure correct polarity. It is recommended to connect both power inputs for redundancy.
- Gauge Kawat: Use 12-24 AWG (0.2 to 2.5 mm²) wires for power connections.
- Torsi: Tighten terminal block screws to 0.5 Nm (4.4 lb-in).
5.3 Sambungan Jaringan
- Ethernet (Modbus TCP): Connect an Ethernet cable from the gateway's RJ45 port to your Modbus TCP network switch or controller.
- CAN (CANopen/J1939): Connect the CAN bus wires (CAN_H, CAN_L, GND) to the corresponding terminals on the gateway. Ensure proper termination resistors are used on the CAN bus as per CAN specifications.
5.4 Konfigurasi Awal
The MGate 5121-T can be configured via its web console. By default, the device obtains an IP address via DHCP. If no DHCP server is available, it will revert to a default static IP address (e.g., 192.168.1.254).
- Connect your PC to the same network as the gateway.
- Buka a web browser and enter the gateway's IP address.
- Log in using the default credentials (refer to the Quick Installation Guide for default username/password).
- Configure the CANopen/J1939 and Modbus TCP settings according to your network requirements.
6. Ngoperasikeun Gerbang
6.1 Operasi Dasar
Once configured, the MGate 5121-T operates as a protocol converter, transparently translating data between the CANopen/J1939 network and the Modbus TCP network. Modbus TCP masters can read/write data from/to CANopen/J1939 slaves mapped within the gateway's configuration.
6.2 Indikator LED
The gateway features several LED indicators to provide status information:
- PWR1/PWR2: Solid green when power input is active.
- STATUS: Indicates device operational status (e.g., solid green for normal operation, blinking for errors). Refer to the full user manual for detailed status codes.
- BISA: Indicates CAN bus activity (e.g., blinking when data is transmitted/received).
- LAN (Link/Act): Solid green for link, blinking for activity on the Ethernet port.
Note: No suitable product videos were provided in the input data for embedding. If available, a video demonstrating LED indicator behavior or initial web configuration steps would be placed here with a descriptive text description.
7. Pangropéa
7.1 beberesih
Periodically clean the exterior of the device with a soft, dry cloth. Do not use liquid or aerosol cleaners, as they may damage the device.
7.2 Apdet firmware
Moxa may release firmware updates to improve performance, add features, or address security vulnerabilities. Check the Moxa website regularly for the latest firmware versions and instructions on how to perform updates.
7.3 Pertimbangan Lingkungan
Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage and ensure reliable operation.
8. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| No Power LED (PWR1/PWR2) | No power supply connected or faulty power supply/cabling. | Check power connections, power supply voltage, and cable integrity. Ensure polarity is correct. |
| Taya Patalina Ethernet | Faulty Ethernet cable or network device. Incorrect network settings. | Verify Ethernet cable connection. Check network switch/router status. Confirm IP address settings. |
| No CAN Communication | Incorrect CAN wiring, missing termination resistors, or incorrect CAN bus parameters. | Check CAN_H/CAN_L wiring. Ensure 120Ω termination resistors are present at both ends of the bus. Verify CAN baud rate and other parameters in configuration. |
| Modbus TCP Master cannot access CAN devices | Incorrect Modbus TCP mapping or CANopen/J1939 device configuration. | Review the gateway's Modbus TCP mapping table. Verify CANopen/J1939 device IDs and object dictionary entries. |
8.1 Reset pabrik
If the device becomes unresponsive or configuration issues persist, a factory reset may be necessary. Refer to the full user manual for the specific procedure, which typically involves pressing and holding a reset button for a certain duration.
9. Spésifikasi
| Parameter | Nilai |
|---|---|
| Modél | MGate 5121-T |
| Protokol didukung | CANopen, J1939, Modbus TCP |
| CAN Port | 1 x CAN (DB9 or Terminal Block, depending on variant) |
| Port Ethernet | 1 x 10/100BaseT(X) auto-negotiating, RJ45 |
| Masukan Voltage | 12-48 VDC (Redundant inputs) |
| Konsumsi Daya | Typically < 5 W (Exact value varies by operation) |
| Suhu Operasi | -40 nepi ka 75°C (-40 nepi ka 167°F) |
| Suhu Panyimpenan | -40 nepi ka 85°C (-40 nepi ka 185°F) |
| Kalembaban | 5 nepi ka 95% RH (non-condensing) |
| Ukuran (W x D x H) | Specific dimensions vary; refer to product datasheet. |
| Parumahan | Metal, panyalindungan IP30 |
| Pamasangan | DIN-rail, Wall-mount |
| Sertifikasi | CE, FCC, UL (Specific certifications vary by region/model) |
10. Garansi jeung Rojongan
10.1 Garansi Produk
Moxa products are covered by a limited warranty. The warranty period and terms vary by product and region. Please refer to the warranty card included with your product or visit the official Moxa websitus kanggo inpormasi garansi lengkep.
10.2 Rojongan Téknis