Topcon TP-L6B

Topcon TP-L6B Pipe Laser Instruction Manual

1. Bubuka

The Topcon TP-L6B Pipe Laser is a precision instrument designed for accurate pipe laying, trenching, sewer, mining, and tunneling projects. Its compact design, extended battery life, and advanced mobile application integration enhance operational efficiency and safety on job sites. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your TP-L6B Pipe Laser.

2. Fitur Produk

  • Up to 60-hour battery life for extended operation.
  • Compact design allows for flexible setup in confined spaces and tighter invert measurements.
  • Mobile application for Android devices enables remote display, configuration, and adjustments, improving safety by reducing the need to enter manholes.
  • Multi-use battery system compatible with other Topcon job site equipment.
  • Includes RC-500 remote control with a range of 600 feet.
  • Wide grade range of -15% to 40% for diverse project requirements.
  • Class II laser with 4.5 mW output.

3. Setélan

Proper setup is crucial for accurate measurements and safe operation. Follow these steps to prepare your TP-L6B Pipe Laser for use.

3.1 Ngabongkar sareng Inspeksi

  1. Carefully remove the TP-L6B Pipe Laser and all accessories from its packaging.
  2. Pariksa unitna pikeun tanda-tanda karusakan anu mungkin kajantenan nalika pengiriman. Upami kapendak karusakan, langsung hubungi supplier anjeun.
  3. Pastikeun yén sadaya komponén anu didaptarkeun dina daptar bungkusan aya.

3.2 Pamasangan Batré sareng Ngecas

  • The TP-L6B uses a rechargeable NiMH battery. Ensure the battery is fully charged before initial use.
  • Locate the battery compartment, typically secured by a latch or screw mechanism.
  • Insert the charged battery, ensuring correct polarity. Close and secure the compartment.
  • Refer to the separate battery charger manual for detailed charging instructions.

3.3 Initial Placement and Leveling

Place the pipe laser on a stable, level surface or mount it securely within the pipe. The integrated adjustable legs assist in initial positioning.

Topcon TP-L6B Pipe Laser unit, showing the control panel, handle, and adjustable legs.

This image displays the Topcon TP-L6B Pipe Laser, a compact yellow and gray device with a sturdy handle, a digital control panel, and two adjustable metal legs for stable positioning.

4. Parentah Operasi

This section outlines the basic steps for operating the TP-L6B Pipe Laser.

4.1 Powering on / Pareum

  • To power on the unit, press and hold the green power button located on the control panel until the display illuminates.
  • Pikeun mareuman, pencét jeung tahan tombol daya deui nepi ka tampilan pareum.

4.2 Ngagunakeun Control Panel

The control panel features a digital display and several buttons for direct control:

  • Tombol panah: Used to adjust grade, line, or other settings.
  • SET/B Button: Confirms selections or accesses specific settings.
  • Tombol MENU: Navigates through the laser's menu options.
  • CENTER Button: Automatically centers the laser beam.

4.3 Remote Control (RC-500) Operation

The RC-500 remote control allows for convenient adjustments from a distance of up to 600 feet. Ensure the remote has fresh batteries and is pointed towards the laser's receiver window.

  • Use the remote's buttons to adjust grade, line, and access menu functions without physically interacting with the unit.
  • The remote can control the laser's grade range from -15% to 40%.

4.4 Mobile App Integration

The Topcon TP-L6B can be controlled and monitored via a dedicated mobile application for Android devices. This app provides a visual interface for settings and adjustments, enhancing safety and ease of use.

  1. Download the official Topcon TP-L6B app from the Android app store.
  2. Pastikeun Bluetooth alat sélulér anjeun diaktipkeun.
  3. Open the app and follow the on-screen instructions to pair with your TP-L6B unit.
  4. Once connected, you can remotely configure settings, monitor status, and make adjustments.

5. Pangropéa

Regular maintenance ensures the longevity and accuracy of your TP-L6B Pipe Laser.

5.1 beberesih

  • After each use, wipe down the exterior of the unit with a soft, damp lawon.
  • Do not use abrasive cleaners or solvents, as these can damage the housing or display.
  • Keep the laser aperture clean and free of dust or debris to maintain beam clarity. Use a soft, lint-free cloth for this purpose.

5.2 Perawatan Batré

  • Always fully charge the battery before storage if the unit will not be used for an extended period.
  • Simpen batré di tempat anu tiis sareng garing.
  • Hindari suhu anu ekstrim, anu tiasa ngirangan umur batré.

5.3 Panyimpenan

When not in use, store the TP-L6B Pipe Laser in its original carrying case in a dry, temperature-controlled environment to protect it from dust, moisture, and impact.

6. Cara ngungkulan

This section provides solutions to common issues you might encounter with your TP-L6B Pipe Laser.

6.1 Laser Not Powering On

  • Pariksa batré: Pastikeun batréna geus dicas pinuh tur dipasang bener.
  • Tombol Daya: Confirm the power button is pressed and held sufficiently.

6.2 Kadali Jauh Teu Ngabales

  • Batré: Replace the batteries in the RC-500 remote control.
  • Garis Panempoan: Ensure there is a clear line of sight between the remote and the laser's receiver.
  • Jarak: Verify you are within the 600-foot operating range.

6.3 Bacaan teu akurat

  • Stabilitas: Ensure the laser is placed on a stable surface and is not subject to vibrations.
  • Kalibrasi: If persistent inaccuracies occur, the unit may require professional calibration. Contact Topcon support.
  • Halangan: Check for any obstructions in the laser beam path.

For issues not covered here, please refer to the official Topcon support resources or contact customer service.

7. Spésifikasi

SpésifikasiRincian
merekTopcon
Nomer modél1034437-05
Item Beurat15 pon
BahanLogam, Plastik
Modeu OperasiOtomatis
Sumber DayaBatré Powered
Wattage4.5 Milliwatts
Jenis BatréNiMH (included)
Kelas laserKelas II
Rentang Kelas-15% dugi ka 40%
Rentang Control Jauh600 Feet (RC-500)
Mobile App kasaluyuanalat Android

8. Garansi jeung Rojongan

For information regarding product warranty, service, or technical support, please refer to the warranty card included with your product or visit the official Topcon website. Contacting Topcon customer service directly will provide the most accurate and up-to-date support information.

Dokumén Patali - TP-L6B

Praview TOPCON TP-L4 Series Pipe Laser Instruction Manual
This instruction manual provides detailed guidance on the safe use, operation, and maintenance of the TOPCON TP-L4 series pipe laser instruments, including models TP-L4G, TP-L4A, TP-L4B, and TP-L4BG.
Praview Topcon RL-VH3D Laser Level User Manual - Operation, Calibration, and Safety
Comprehensive user manual for the Topcon RL-VH3D laser level. Learn about its features, how to operate it, perform calibrations, understand safety precautions, and view technical specifications. Includes instructions for setup, scanning modes, and accessories.
Praview Topcon RL-H5A Rotating Laser: Instruction Manual
Comprehensive instruction manual for the Topcon RL-H5A Rotating Laser, covering operation, safety, maintenance, and specifications. Learn how to use and care for your laser leveling instrument.
Praview Topcon YieldTrakk YM-1 Operator's Manual: Yield Monitoring Guide
Essential information for operating and maintaining the Topcon YieldTrakk YM-1 yield monitoring system. Covers safe use, setup, controls, safety, and maintenance for agricultural applications.
Praview Topcon Office v10.0 Release Notes - September 2025
Release notes for Topcon Office version 10.0, detailing new features, enhancements, system requirements, and fixes for September 2025. Includes updates to point timestamping, projections, import/export, property management, area selection, editing tools, surface operations, 3D view, resurfacing, ADAC, and various bug resolutions.
Praview Topcon Motorgrader System Five 9164 Control Box Operator's Manual
Operator's manual for the Topcon Motorgrader System Five, featuring the 9164 Control Box. Provides guidance on system overview, operation, calibration, maintenance, and troubleshooting for efficient grading operations.