This manual provides detailed instructions for the proper use, setup, operation, and maintenance of your SHAHE Digital Torque Adapter, model ANC-30. This high-precision digital torque adapter is designed for accurate torque measurement in various applications, including automotive, bicycle, motorcycle, and general home repairs. Please read this manual thoroughly before operating the device to ensure safe and efficient use.

Image 1.1: The SHAHE Digital Torque Adapter ANC-30, shown with its primary 1/2-inch drive and two included adapter sizes (3/8-inch and 1/4-inch) for versatile use.
2. Émbaran Kasalametan
Salawasna merhatikeun pancegahan kaamanan di handap ieu pikeun nyegah tatu atanapi karusakan kana alat:
- Do not exceed the maximum torque capacity of 30 N.m. Over-torquing can damage the adapter and the fastener.
- Ensure the adapter is securely attached to your wrench and the socket/fastener before applying torque.
- Keep the device clean and dry. Avoid exposure to extreme temperatures or corrosive environments.
- Ulah nyobian ngabongkar atawa ngaropéa alat. Perbaikan ngan kedah dilakukeun ku tanaga anu mumpuni.
- Simpen alat dina wadah pelindungna nalika teu dianggo pikeun nyegah karusakan.
- Jauhkeun batré tina jangkauan barudak.
3. Produk Langkungview
3.1 Komponén Kaasup
The SHAHE Digital Torque Adapter ANC-30 package includes:
- 1 x SHAHE Digital Torque Adapter ANC-30
- 1 x Manual Instruksi (Dokumén ieu)
- 2 x Batré AAA
- 1 x Kasus Panyimpenan
- 1 x Adaptor 1/2" dugi ka 3/8"
- 1 x Adaptor 1/2" dugi ka 1/4"

Image 3.1: The SHAHE Digital Torque Adapter ANC-30, its instruction manual, and the included adapters stored within its protective carrying case.
3.2 Komponén alat jeung kadali
Familiarize yourself with the various parts and controls of the digital torque adapter:

Image 3.2: Labeled diagram of the SHAHE Digital Torque Adapter ANC-30, indicating the display screen, control buttons, indicator light, and buzzer location.
- Layar tampilan: Shows torque readings, units, and mode.
- Tombol '+': Ningkatkeun nilai atanapi navigasi ménu.
- '-' Tombol: Ngurangan nilai atanapi navigasi ménu.
- 'M' (Save) Button: Used for mode selection and saving settings.
- 'U/S' (Setting) Button: Used for unit selection and system settings.
- 'P/C' (Switch) Button: Power on/off and peak/track mode selection.
- Lampu Indikator: Provides visual feedback, especially for alarm functions.
- Buzzer (rear): Provides audible feedback, especially for alarm functions.
- Switch (Drive): The 1/2-inch square drive for attaching sockets or adapters.
4. Setélan
4.1 Pamasangan batré
The device requires two AAA batteries (included). To install:
- Teang tempat panutup kompartemen batre dina tonggong alat.
- Buka panutup.
- Pasangkeun dua batré AAA, pastikeun polaritasna bener (+/-).
- Tutup panutup kompartemen batré aman.
4.2 Attaching Adapters and Sockets
The SHAHE Digital Torque Adapter ANC-30 features a 1/2-inch drive. Use the included adapters to fit 3/8-inch and 1/4-inch drive sockets.

Image 4.1: The digital torque adapter with its native 1/2-inch drive, shown next to the 3/8-inch and 1/4-inch drive adapters for connecting various socket sizes.
- Select the appropriate adapter (1/2\" to 3/8\" or 1/2\" to 1/4\") if your socket is not 1/2-inch.
- Firmly attach the adapter to the 1/2-inch drive of the digital torque adapter.
- Attach your desired socket to the adapter or directly to the 1/2-inch drive.
- Pastikeun sadaya konéksi aman sateuacan dianggo.
5. Parentah Operasi
5.1 Daya Hurung/Pareuman
- Daya Hurung: Press the 'P/C' button to turn on the device. The display will light up.
- Pareum listrik: Press and hold the 'P/C' button for a few seconds to turn off the device. The device will also automatically power off after 5 minutes of inactivity to conserve battery life.
5.2 Pilihan Unit
The adapter supports four torque units: N.m, ft.lb, in.lb, and kgf.cm.

Gambar 5.1: Examples of the digital display showing torque values in lbf.ft, lbf.in, kgf.cm, and N.m, demonstrating the unit conversion capability.
- With the device powered on, press the 'U/S' button repeatedly to cycle through the available units (N.m, ft.lb, in.lb, kgf.cm).
- Pilih unit anu dipikahoyong pikeun pangukuran anjeun.
5.3 Modeu pangukuran
The device offers three measurement modes: Real-time (Track), Peak, and Preset.
- Real-time Mode (Track): Displays the current torque being applied. This is useful for monitoring torque as it is being applied. To select, press the 'M' button until \"track\" appears on the display.
- Mode puncak: Captures and displays the maximum torque value reached during the application. This is useful for verifying the highest torque applied. To select, press the 'M' button until \"peak\" appears on the display.
- Modeu prasetél: Allows you to set a target torque value. The device will provide an audible and visual alarm when the target torque is approached and reached. To select, press the 'M' button until \"preset\" appears on the display.
5.4 Setting Target Torque (Preset Mode)
When in Preset Mode:
- Enter Preset Mode by pressing the 'M' button.
- Press the 'U/S' button to enter the setting interface. The target torque value will flash.
- Use the '+' and '-' buttons to adjust the target torque value.
- Press the 'U/S' button again to confirm the setting.
5.5 Applying Torque and Alarm Function
Once the mode and unit are selected, apply torque to the fastener. The device will display the torque value in real-time (Track mode) or capture the peak (Peak mode).

Image 5.2: The digital torque adapter showing its alarm function in action, with a red indicator light and an audible alert when the preset torque value is reached.
- Alarm Kadéngé jeung Visual: In Preset Mode, as you approach the target torque, the device will emit a continuous beep and the indicator light will flash. When the target torque is reached, the beep will become continuous and the red indicator light will stay solid.
- Stop applying torque immediately when the alarm indicates the target has been reached to avoid over-torquing.
6. Pangropéa sarta perawatan
- beberesih: Ngusap alat ku kaén anu lemes sareng garing. Ulah make cleaners abrasive atawa pangleyur.
- Panyimpenan: Store the digital torque adapter in its protective case in a dry, cool place, away from direct sunlight and extreme temperatures.
- Ngagantian batré: Replace batteries when the low battery indicator appears on the display. Remove batteries if the device will not be used for an extended period to prevent leakage.
- Kalibrasi: For professional applications requiring certified accuracy, periodic calibration by a qualified service center is recommended.
7. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Alat teu hurung. | Batré paéh atawa salah dipasang. | Pariksa polaritasna batré. Ganti ku batré AAA anyar. |
| Bacaan teu akurat. | Device not properly zeroed or requires calibration. | Ensure the device is at rest before powering on. If issues persist, consider professional calibration. |
| Alarm not functioning. | Not in Preset Mode or alarm volume is too low (if adjustable). | Ensure the device is in Preset Mode. Check manual for alarm volume adjustment (if applicable). |
| Tampilanna taram atawa kedip-kedip. | Daya batre lemah. | Ganti batré. |
8. Spésifikasi
| Modél | ANC-30 |
| Rentang Ukur | 0.9 - 30 N.m |
| Minimum Division Value | 0.01 Nm |
| Akurasi | ±2% (Clockwise), ±2.5% (Counter-clockwise) |
| Ukuran Drive | 1/2 inch (includes 3/8 inch and 1/4 inch adapters) |
| Modeu pangukuran | Real-time (Track), Peak, Preset |
| Hijian | N.m, ft.lb, in.lb, kgf.cm |
| Bahan | Alloy Steel |
| Sumber Daya | 2 x Batré Alkali AAA (kaasup) |
| Pareum Otomatis | Saatos 5 menit teu aktip |
| Item Beurat | 0.45 kg (15.8 ons) |
| Produsén | Wenzhou Sanhe Measuring Instrument Co.,LTD |
9. Garansi jeung Rojongan