Bubuka
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Total Automatic Self-priming Jet Pump, model TWP415006. Please read this manual thoroughly before operating the pump to ensure proper use and to prevent damage or injury.
Parentah Kasalametan
Salawasna perhatikeun pancegahan kaamanan di handap ieu pikeun ngirangan résiko kahuruan, kejutan listrik, atanapi tatu:
- Kasalametan listrik: Pastikeun catu daya cocog sareng vol pompatage (220-240V~50Hz). Always connect the pump to a properly grounded outlet. Do not operate the pump with a damaged cord or plug.
- Kasalametan cai: Do not pump flammable or corrosive liquids. Ensure the pump is not submerged unless specifically designed for submersible use. Protect the pump from freezing temperatures.
- Pamasangan: Install the pump in a dry, well-ventilated area, protected from direct sunlight and rain. Ensure stable mounting to prevent vibration.
- Pangropéa: Disconnect power before performing any maintenance or repairs. Only qualified personnel should perform repairs.
- Barudak jeung Pets: Jauhkeun barudak sareng piaraan tina pompa salami operasi.
Produk Leuwihview jeung Komponén
The Total Automatic Self-priming Jet Pump TWP415006 is designed for efficient water transfer. It includes a 24L cylindrical tank, pressure switch, pressure gauge, stainless steel hose, and brass 3-way connector.

Gambar 1: Leuwihview of the Total Automatic Self-priming Jet Pump TWP415006.

Figure 2: Key features of the pump, including 1500W power, 24L tank, and copper wire motor.
Komponén Kaasup:
- 1 x Automatic Self-priming Jet Pump (1.5kW)
- 1 x 24L Cylindrical Tank
- 1 x Pindah tekanan
- 1 x Stainless Steel Hose
- 1 x Alat Ukur Tekanan
- 1 x Brass 3-way Connector
spésifikasi
| Parameter | Nilai |
|---|---|
| Modél | TWP415006 |
| Voltage | 220-240V~50Hz |
| Dipeunteun Power | 1500W (2.0HP) |
| Max. Aliran | 100 L/min |
| Max. Sirah | 60m |
| Max. Nyeuseup | 9m |
| Diaméter pipa | 1" x 1" |
| Tipe Motor | Copper Wire Motor |
| Bahan Impeller | Beusi sténless |
| Awak Pompa | Éléktroforésis |
| Bahan Aci | Stainless Steel Welding (304+45#) |
| Panjang kabel | 0.3m |
| Item Beurat | 32 kg |
| Ukuran Paket | 62.7 x 57.3 x 36 cm |
Disetél
1. Panempatan
- Choose a flat, stable, and dry location for the pump, protected from direct weather exposure.
- Pastikeun ventilasi anu cekap di sakitar pompa.
- Position the pump as close as possible to the water source to minimize suction lift.
2. Sambungan Pipa
- Pipa Nguseup: Connect a rigid pipe of 1" diameter to the suction inlet. Ensure the suction pipe is airtight to prevent air leaks, which can affect priming and pump performance. Install a foot valve with a strainer at the end of the suction pipe in the water source to prevent debris from entering the pump and to maintain prime.
- Pipa Discharge: Connect a 1" diameter pipe to the discharge outlet. The included stainless steel hose and brass 3-way connector should be used for the pressure tank and pressure gauge connection.
- Use thread sealant tape on all threaded connections to ensure a watertight seal.
3. Sambungan Listrik
- Ensure the power supply is 220-240V~50Hz.
- Connect the pump to a dedicated, properly grounded electrical outlet.
- Do not use extension cords unless absolutely necessary, and if so, ensure they are rated for outdoor use and the pump's power requirements.
4. Priming Pompa
- Before first use, or if the pump has run dry, it must be primed.
- Locate the priming plug on the top of the pump casing.
- Remove the priming plug and slowly fill the pump casing ku cai beresih nepi ka ngalembur.
- Ngaganti colokan priming aman.
- Ensure the discharge valve is open before starting the pump.
Parentah Operasi
1. Mimitian Pompa
- Ensure the pump is properly primed (see Setup section).
- Pastikeun sadaya sambungan aman sareng bebas bocor.
- Plug the pump into the grounded electrical outlet. The pump will start automatically when pressure drops below the set point of the pressure switch.
2. Operasi Pemantauan
- Observe the pressure gauge to ensure the system is operating within expected pressure ranges.
- Listen for unusual noises or vibrations, which may indicate a problem.
- Check for any leaks around connections.
3. Pareuman
- To stop the pump, simply unplug it from the power source. The automatic pressure switch will also stop the pump when the desired pressure is reached.
- For extended periods of non-use, especially in freezing conditions, drain the pump and pipes completely to prevent damage.
Pangropéa
1. Cék Biasa
- Periodically inspect the pump and all connections for signs of wear, damage, or leaks.
- Check the pressure tank's air charge annually. Refer to the tank's specific instructions for proper air pressure.
- Ensure the foot valve strainer is clear of debris.
2. beberesih
- Keep the pump exterior clean and free of dust and dirt to ensure proper cooling.
- Entong nganggo bahan kimia kasar atanapi beberesih kasar.
3. Persiapan usum tiris (pikeun iklim tiis)
- If the pump is installed in an area subject to freezing temperatures, it must be drained completely to prevent damage from ice expansion.
- Disconnect power, open all drain plugs, and remove the priming plug to allow all water to escape.
- Store the pump in a warm, dry place if possible.
Pamérésan masalah
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pompa teu ngamimitian | No power; tripped circuit breaker; faulty motor. | Check power connection and circuit breaker. Consult a qualified electrician if motor is suspected faulty. |
| Pompa jalan tapi cai teu ngocor | Pump not primed; air leak in suction line; clogged foot valve/strainer; low water level in source. | Re-prime the pump. Check all suction connections for leaks. Clean foot valve strainer. Ensure adequate water in source. |
| Tekanan atanapi aliran anu handap | Partial air leak; clogged impeller; worn components; incorrect pipe size. | Check suction line for small leaks. Inspect and clean impeller. Consult service for worn parts. Ensure correct pipe diameter. |
| Ngompa siklus teuing | Pressure tank air charge too low; leak in system; faulty pressure switch. | Check and adjust pressure tank air charge. Inspect entire system for leaks. Test or replace pressure switch. |
| Noise/geter kaleuleuwihan | Cavitation (air in pump); loose mounting; bearing wear. | Ensure pump is primed and no air leaks. Secure pump mounting. Consult service for bearing issues. |
Garansi sareng Rojongan
TOTAL products are manufactured to high-quality standards and are guaranteed against manufacturing defects. For warranty claims or technical support, please contact your local TOTAL authorized service center or the retailer from whom you purchased the product. Please retain your proof of purchase for warranty validation.
Pikeun pitulung salajengna, anjeun tiasa nganjang ka TOTAL Store on Amazon.