ACiQ B0DHFF2DKL

Manual Pangguna Sistem Pompa Panas Inverter Sentral ACiQ 2.5 Ton 17 SEER2

Model: B0DHFF2DKL

1. Bubuka

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Émbaran Kasalametan

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Kasalametan listrik: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Penanganan Refrigerant: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Pamasangan: Pamasangan kedah dilakukeun ku ahli HVAC anu gaduh lisénsi.
  • Alat Pelindung Pribadi: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Fitur konci

  • Téknologi Inverter: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Efisiensi Tinggi: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Lega Rentang Operasi: Reliable performance from -13°F to 122°F.
  • Operasi sepi: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Komponén awét: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Refrigerant Eco-Friendly: Utilizes R-454B refrigerant.
  • Instalasi fléksibel: Supports horizontal and vertical air handler installation.
  • Kadali pinter: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. komponén Leuwihview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Unit Pangolah Udara Jero Ruangan
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • Termostat WiFi
  • Pelindung Operasi
  • Adaptor Ngecas CPS
  • Tembok leungeun baju
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Gambar 1: Leuwihview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Setup jeung Instalasi

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Cék Pra-Pamasangan

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Pastikeun rohangan anu cekap pikeun unit indoor sareng outdoor, supados aliran hawa sareng aksés pangropéa tiasa lancar.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Gambar 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Penempatan Unit Luar Ruangan

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Gambar 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Parentah Operasi

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Modeu Operasi Dasar

  • Modeu tiis: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Mode pemanasan: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Modeu kipas: Sirkulasi hawa tanpa pemanasan atawa cooling.
  • Modeu Otomatis: Otomatis pindah antara pemanasan sareng pendinginan pikeun ngajaga suhu anu disetel.
ACiQ outdoor unit operating in extreme heat

Gambar 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Gambar 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Kontrol Pinter

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Gambar 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Pangropéa

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Ngaganti Saringan Udara: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Ngabersihan Unit Luar: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Sistim drainase: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Pamariksaan profésional: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Cara ngungkulan

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Henteu aya kakuatan: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Insufficient Heating/Cooling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Sora anu teu biasa: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • bocor cai: Check condensate drain line for blockages.

9. Spésifikasi

Dimensions of ACiQ indoor and outdoor units

Gambar 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Gambar 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Gambar 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

FiturRincian
Kamampuh cooling31,000 BTU / jam
Kapasitas pemanasan30,000 BTU/hr (at 47°F)
Peunteun SEER218.8
Rating HSPF29.7
Tipe RefrigerantR-454B
Jero rohangan Unit Power Supply115/208/230V, 60Hz, 1Ph
Unit outdoor Power Supply208/230V, 60Hz, 1Ph
Max Piping Panjang164 ft (50m)
Bédana Jangkungna Maksimum82 ft (25m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Jero rohangan Unit Beurat Net128.97 pon
Beurat Bersih Unit Luar Ruangan164.02 pon

10. Garansi jeung Rojongan

ACiQ offers a comprehensive warranty for this heat pump system:

  • Garansi Bagian: 7 taun
  • Garansi Compressor: 12 taun

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ websitus.

Dokumén Patali - B0DHFF2DKL

Praview ACiQ 9K-24K Standard Heat Single-Zone Systems: Installation & Owner's Manual
ACiQ 9K-24K Standard Heat Single-Zone Systems Installation & Owner's Manual. This guide details installation, operation, safety, and maintenance for ACiQ air conditioners, including model specifics and R454B refrigerant information.
Praview Manual Pamasangan Sistem Inverter Sentral ACiQ
Manual pamasangan lengkep pikeun Sistem AC sareng Pompa Panas Inverter Sentral ACiQ, anu ngajelaskeun sacara rinci tindakan pencegahan kaamanan, pipa refrigeran, pamasangan unit luar ruangan, kabel, spésifikasi daya, evakuasi hawa, sareng prosedur uji coba.
Praview ACiQ Wall-Mounted Air Handler & Extreme Heat Single-Zone Condenser Installation & Owner's Manual
This manual provides detailed installation, operation, and safety guidelines for ACiQ wall-mounted air handlers and extreme heat single-zone condensers, covering models ACIQ-06W-HH-MD through ACIQ-24ZPL-HP230C.
Praview Manual Pamasangan Unit Luar Ruangan Sistem Inverter Sentral ACiQ
Manual pamasangan lengkep pikeun unit luar ruangan ACiQ Central Inverter Systems, anu ngawengku tindakan pencegahan kaamanan, pipa refrigeran, kabel, pamasangan unit, sareng prosedur uji coba pikeun modél sapertos ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, sareng anu sanésna.
Praview Sistem Pompa Panas Ducted ACiQ Generasi Salajengna: Panduan Mimitian Gancang pikeun Kabel Termostat
This guide provides essential information for connecting and wiring thermostats to the ACiQ Next Gen Ducted Heat Pump System. It details recommended and alternative connection options, including DIP switch settings and terminal block configurations for various thermostat types.
Praview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.