FireAngel SW1-R

FireAngel SW1-R Mains Powered Optical Smoke Alarm User Manual

Model: SW1-R

1. Produk Langkungview

The FireAngel SW1-R is a mains-powered optical smoke alarm designed to provide early warning of fire. It features a 9V backup battery to ensure continuous protection during power outages. The alarm emits a loud 85dB sound at 3 meters and includes LED visual indicators for clear alerts.

This optical smoke alarm is particularly effective at detecting slow-burning fires that produce thick white smoke, making it suitable for general living areas.

Fitur konci:

FireAngel SW1-R Smoke Alarm front view

Gambar 1: Hareupeun view of the FireAngel SW1-R Mains Powered Optical Smoke Alarm.

FireAngel SW1-R Smoke Alarm with packaging and key features

Figure 2: FireAngel SW1-R Smoke Alarm highlighting its 9V backup battery, audible/visual alerts, and large test button.

2. Émbaran Kasalametan penting

Mangga baca sakabeh parentah taliti saméméh instalasi tur operasi. Simpen manual ieu pikeun rujukan ka hareup.

FireAngel SW1-R Smoke Alarm placement guidelines

Figure 3: Illustration of recommended placement guidelines for the smoke alarm, showing distance from walls and light fittings, and unsuitable locations.

3. Eusi Paket

Pariksa heula sadaya barang aya sareng teu ruksak nalika dibuka bungkusanna:

4. Pitunjuk Instalasi

penting: Installation should only be performed by a competent person or qualified electrician. Ensure the mains power supply is switched off at the consumer unit before commencing installation.

4.1. Léngkah-léngkah Pra-Pasang:

  1. Pilih Lokasi: Choose a suitable location on the ceiling, adhering to the placement guidelines (refer to Section 2).
  2. Pegatkeun Daya: Turn off the mains electricity supply to the circuit where the alarm will be installed.
  3. Install Backup Battery: Open the battery compartment on the alarm unit and insert the supplied 9V battery, observing polarity. Close the compartment securely.

4.2. Mounting the Alarm:

  1. Tanda titik pangeboran: Hold the base plate against the ceiling at your chosen location and mark the two drilling points.
  2. liang bor: Drill holes at the marked points and insert the rawl plugs.
  3. Gunung Base Plate: Secure the base plate to the ceiling using the provided screws.
  4. Sambungkeun Wiring: Connect the mains wiring (Live, Neutral, Earth, and Interlink if applicable) to the terminal block provided. Ensure connections are secure and correct. The alarm unit connects to this terminal block.
  5. Attach Alarm Unit: Align the smoke alarm unit with the base plate and twist clockwise until it clicks securely into place.
FireAngel SW1-R Smoke Alarm easy installation steps

Figure 4: Visual guide for easy installation, showing steps like installing the backup battery, mounting the bracket, attaching the alarm, and connecting to mains power.

4.3. Interlinking Multiple Alarms:

The SW1-R can be hardwired and interconnected with up to 12 compatible FireAngel mains-powered smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms. To interlink, connect the interlink wire between the designated terminals on each alarm's base plate. When one interlinked alarm detects a hazard, all connected alarms will sound simultaneously.

4.4. Post-Installation Check:

  1. Mulangkeun Daya: Turn the mains electricity supply back on.
  2. Uji Alarm: Press and hold the Test/Silence button for 5 seconds to confirm the alarm is functioning correctly. A loud, high-pitched sound indicates proper operation.

5. Parentah Operasi

5.1. Operasi Normal:

Under normal conditions, the alarm will periodically flash its LED indicator to show it is powered and monitoring for smoke. If smoke is detected, the alarm will sound a loud siren and the LED will flash rapidly.

5.2. Test/Silence Button:

5.3. Sleep Easy Function:

If the 9V backup battery is low, the alarm will emit a regular "chirp" sound. To temporarily silence these low battery chirps for up to 8 hours, press the Test/Silence button. This allows for an uninterrupted night's sleep while still maintaining protection. Replace the battery as soon as possible after using this function.

6. Pangropéa

Regular maintenance ensures the continued reliability and effectiveness of your smoke alarm.

FireAngel SW1-R Smoke Alarm maintenance tips

Figure 5: Visual summary of key maintenance recommendations for the smoke alarm, including monthly testing and quarterly vacuuming.

7. Cara ngungkulan

If your smoke alarm is not operating as expected, refer to the following table for common issues and solutions:

MasalahMungkin Cukang lantarananaSolusi
Alarm chirps intermittentlyLow 9V backup battery.Replace the 9V battery immediately. Use the Sleep Easy function if needed for temporary silence.
Alarm sounds without visible smoke (false alarm)Dust or debris in the sensing chamber; high humidity; cooking fumes; steam.Press the Test/Silence button to temporarily silence. Vacuum the alarm thoroughly. Relocate the alarm if it's consistently affected by cooking fumes or steam.
Alarm henteu disada nalika tésNo mains power; flat 9V backup battery; faulty unit.Check mains power supply. Replace 9V battery. If problem persists, contact customer support.
Interlinked alarms do not all soundFaulty interlink wiring; incompatible alarms; too many alarms interlinked.Check interlink wiring connections. Ensure all interlinked alarms are compatible FireAngel models. Do not exceed 12 interlinked alarms.

8. Spésifikasi Téknis

Nomer modélSW1-Sunda
Tipe sénsorOptical (Photoelectric)
Sumber DayaMains Powered (230V AC) with 9V DC Battery Backup
Volume alarem85dB dina 3 méter
Interlink CapabilityUp to 12 compatible FireAngel mains-powered alarms
Ukuran produk (D x W x H)4.2D x 12.6W x 12.6H Sentimeter
Item Beurat220 gram
Suhu OperasiTingal bungkusan produk pikeun rentang husus
Range KelembapanTingal bungkusan produk pikeun rentang husus
StandarBS EN 14604: 2005
UPC816317004422
FireAngel SW1-R Smoke Alarm with UKCA and CE marks

Figure 6: The FireAngel SW1-R Smoke Alarm displaying its UKCA and CE certifications, indicating compliance with safety standards.

9. Garansi sarta Rojongan Palanggan

9.1. Inpormasi Garansi:

The FireAngel SW1-R Mains Smoke Alarm comes with a garansi 5 taun ti tanggal beuli. Garansi ieu nyertakeun cacad dina bahan sareng pagawean dina panggunaan normal. Punten tahan bukti pameseran anjeun pikeun klaim garansi.

The warranty does not cover damage caused by misuse, accidental damage, unauthorized modifications, or failure to follow the instructions in this manual.

9.2. Rojongan Palanggan:

For technical assistance, warranty claims, or further information regarding your FireAngel SW1-R smoke alarm, please contact FireAngel customer support. Refer to the FireAngel official websitus atanapi kemasan produk kanggo kéngingkeun detil kontak anu pangénggalna.

Websitus: www.fireangel.co.uk (Kelample link, link sabenerna bisa rupa-rupa dumasar wewengkon)

Dokumén Patali - SW1-Sunda

Praview Buku Panduan Pangguna Alarm Panas Bertenaga Listrik FireAngel HW1
Buku pituduh lengkep pikeun Alarm Panas FireAngel HW1 anu dikuatkeun ku kakuatan utama kalayan batré cadangan 9V. Ngawengku pamasangan, posisi, fitur silencing, pilihan interkoneksi, pangropéa, ngungkulan masalah, sareng inpormasi garansi.
Praview Buku Panduan Pangguna Alarm Haseup & Panas FireAngel: FA6611, FA6615, FA6620, FA6720
Buku pituduh lengkep pikeun alarm haseup optik FireAngel FA6611, FA6615, FA6620 sareng alarm panas FA6720. Ngawengku pamasangan, pangropéa, ngungkulan masalah, garansi, sareng pembuangan.
Praview Buku Panduan Pangguna Alarm Haseup FireAngel ST-625-INT
Buku panduan lengkep pikeun alarm haseup FireAngel ST-625-INT, anu ngawengku pamasangan, fitur, pangropéa, sareng garansi. Buku panduan ieu nyayogikeun inpormasi kaamanan penting sareng pitunjuk operasional.
Praview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Praview FireAngel SCB10 Kombinasi Haseup jeung Karbon Monoksida Alarm Manual Pamaké
Manual pamaké pikeun FireAngel SCB10, kombinasi haseup jeung karbon monoksida alarem, nyadiakeun parentah komprehensif ngeunaan instalasi, operasi, pangropéa, jeung kaamanan pikeun pamakéan padumukan.
Praview FireAngel FA6611, FA6615, FA6620 Smoke & FA6720 Heat Alarm User Manual
User manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Includes installation, positioning, maintenance, troubleshooting, warranty, and disposal information.