Brainchild E62 PID Temperature Controller

Leuwihview & Appearance

Kenop sareng Pintonan
OPERASI KEYPAD
Konci Gulung: ![]()
This key is used to select a parameter to be viewed atanapi disaluyukeun.
UP/Increase KEY:
Konci ieu dianggo pikeun ningkatkeun nilai parameter anu dipilih.
DOWN/Decrease KEY: ![]()
Konci ieu dianggo pikeun nurunkeun nilai parameter anu dipilih.
SHIFT KEY:
konci ieu dipaké pikeun:
- Move to the digit of the selected parameter and change the value by using up or down key to increase or decrease the value.
Gulung ka luhur: ![]()
Two keys pressed synchronously are used to:
- Go to the previous parameter
RESET: + ![]()
Two keys pressed synchronously are used to:
- Balikkeun tampilan ka layar utama.
- Reset alarm latching sawaktos kondisi alarm dicabut.
- Ngeureunkeun mode kontrol manual, mode Auto-Tuning atawa mode calibration.
- Hapus hiji Auto-Tuning atawa pesen kasalahan komunikasi.
- Enter the manual control menu if a failure mode occurs.
Gulung ka handap: ![]()
Two keys pressed synchronously directly go to the Manual control mode
Asupkeun konci: ![]()
Pencét
jeung tahan salila 5 detik atawa leuwih panjang pikeun:
- Enter the Auto-Tuning mode.
Pintonan bakal nunjukkeun. - Enter the manual control mode.
Pintonan bakal nunjukkeun.
Enter the setup menu mode.
Pintonan bakal nunjukkeun.
Perform calibration of a selected parameter during the calibration procedure. The display will show
Menu geus dibagi kana 5 grup. Aranjeunna kieu:
- Menu Panganggo
- Auto-Tuning Mode Menu
- Menu Mode Manual
- Setup Menu
- Calibration Mode Menu

- Pencét
for the next parameter ; Press
jeung
konci pikeun mulang ka parameter saméméhna. - Pencét jeung tahan
for 3.1 seconds, then let go to select auto tuning mode. - Pencét jeung tahan
for 4.2 seconds, then let go, to select manual control mode. - Pencét jeung tahan
for 5.3 seconds, then let go to select setup mode. - Pencét jeung tahan
salila 6.4 detik, lajeng hayu balik pikeun milih mode calibration.
Menu Panganggo
Paké
key to enter basic menu parameters, and press
again to select SP1, SEL1~SEL8.
Pencét ![]()
to return to the previous.

Auto-Tuning Mode
Pencét
key 5 seconds to activate Auto-Tuning Mode

Menu Mode Manual
Pencét
key 3 seconds to execute the selected default program

Enter Manual Control Mode; refer to Manual 6.1 & 6.8.2~6.8.4

Setup Menu
The setup menu has been categorized into eight categories.
They are listed as below.
- Menu Dasar (basis)
- Menu Kaluaran (kaluar)
- Communication Menu (CoMM)
- User Select Menu (SEL)
Menu Dasar (basis)
Paké
or
key to get bASE in the lower display then use
key to enter to basic menu parameters.

Menu Kaluaran (kaluar)
Paké
or
key to get oUT in the lower display then use
key to enter to output menu parameters.

Communication Menu (CoMM)
Paké
or
key to get CoMM in the lower display then use
key to enter to communication menu parameters.
Please note that confirm A2FN set to CoMM when using communication.

User Select Menu (SEL)
Paké
or
key get SEL in the lower display then use
key to enter to select the user menu parameters.

Modeu Kalibrasi

Pencét
key for 2 seconds or longer (not more than 3 seconds) ; then release it to enter calibration Mode.
Pencét
key for 5 seconds to perform calibration
- Please note that it is required to use specialized equipment to apply calibration, attempting to change will affect device accuracy
Catetan:
- Using Manual, Auto-Tuning, Calibration modes will break the control loop and change some of the previous setting data. Make sure that the system is allowable to apply these modes.
- The flow chart shows a complete list of all parameters. For actual application, the number of available parameters will vary depending on the setup and model of the controller and will be less than that shown in the flow chart.
- The user can select up to 8 parameters to put in the user select menu by using the SEL1~SEL8 parameters in the setup menu
Before you Start, Setup Input/Output
After power-up, press and hold
for 5.3 seconds, then let go to enter Setup Menu. Complete Parameter setting, INPT, UNIT, DP, O1TY, O1L and O1H.
- Enter the Setup Menu. Press
for 5 seconds to enter Basic Menu (bASE). Finish setting for INPT, UNIT and DP. Exit the level. - Return to the Setup Menu. Press
for 5 seconds to enter Output Menu (oUT). Finish setting for O1TY, O1L and O1H. Press and hold
and return to homepage.

OP1L/ OP1H Table
| Rentang | OP1L | OP1H | |
| OM9A-3 | 4-20 | 20.0 | 100.0 |
| OM9A-3 | 0-20 | 0.0 | 100.0 |
| OM9A-5 | 0-5V | 0.0 | 50.0 |
| OM9A-5 | 1-5V | 10.0 | 50.0 |
| OM9A-5 | 0-10 | 0.0 | 100.0 |
* When O1TY as DC.MA or DC. Vo, set the value based on usage requirement
Sambungan Terminal

Notasi Parameter
User Menu Parameter
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés | |
| 0 | SP1 | Set Point 1 | Handap: SP1L
Luhur: SP1H |
25.0 °C | Urang Sunda/W | |
| 64 | PV | Nilai prosés | Handap: -19999
Luhur: 45536 |
(77.0 °F) | R | |
| 65 | SV | Current set point value | Handap: SP1L
Luhur: SP1H |
—— | R | |
| 44 |
SEL1 |
Select 1st parameter for user menu | 0 Euweuh
1 A1SP 2 A2SP 3 KUNCI 4 INPT 5 PB 6 TI |
7 TD
8 SHIF 9 OFST 10 O1HY 11 A1HY 12 A2HY 13 ADDR |
—— | Urang Sunda/W |
| 45 | SEL2 | Select 2nd parameter | Select 2nd parameter for user manual. Same as the SEL1 | 0 | Urang Sunda/W | |
| 46 | SEL3 | Select 3rd parameter | Select 3rd parameter for user manual. Same as the SEL1 | 0 | Urang Sunda/W | |
| 47 | SEL4 | Select 4th parameter | Select 4th parameter for user manual. Same as the SEL1 | 0 | Urang Sunda/W | |
| 48 | SEL5 | Select 5th parameter | Select 5th parameter for user manual. Same as the SEL1 | 0 | Urang Sunda/W | |
| 49 | SEL6 | Select 6th parameter | Select 6th parameter for user manual. Same as the SEL1 | 0 | Urang Sunda/W | |
| 50 | SEL7 | Select 7th parameter | Select 7th parameter for user manual. Same as the SEL1 | 0 | Urang Sunda/W | |
| 51 | SEL8 | Select 8th parameter | Select 8th parameter for user manual. Same as the SEL1 | 0 | Urang Sunda/W | |
Manual Mode Parameter
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés |
| 66 | MV1 | Output 1 %Value | Handap: 0.00
Luhur: 100.00% |
—– | R (R/W,
manual) |
Basic (bASE) Parameter
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés |
| 3 | KUNCI | Select parameters to be locked | 0 None: No parameter is locked
1 SEt: Setup data are locked 2 uSEr: Setup data and user data are locked. SetPoint are unlocked. 3 ALL: All data are locked |
0 | Urang Sunda/W |
| 4 | INPT | Input sensor selec- tion | 0 J_tC: J tipe Thermocouple
1 K_tC: K tipe Thermocouple 2 t_tC: T type Thermocouple 3 R_tC: R tipe Thermocouple 4 S_tC: S type Thermocouple 5 Pt. dN: PT 100 DIN 6 Pt.JS: PT 100 JIS |
1 | Urang Sunda/W |
| 5 | UNIT | Pilihan unit input | 0 oC: °C unit
1 oF: °F unit |
0 | Urang Sunda/W |
| 6 | DP | Decimal point selec- tion | 0 No.dP: no decimal point
1 1-dP: 1 decimal point |
1 |
Urang Sunda/W |
|
9 |
SP1L |
Low limit of set point value | rendah:
J_TC: -120.0°C (-184.0°F) K_TC: -200.0°C (-328.0°F) T_TC: -250.0°C (-418.0°F) R_TC: 0.0°C ( 32.0°F) S_TC: 0.0°C ( 32.0°F) PTDN: -200.0°C (-328.0°F) PTJS: -200.0°C (-328.0°F) Luhur: SP1H |
-17.8 °C
(0.0 °F) |
Urang Sunda/W |
| 10 |
SP1H |
High limit of set point value | Handap: SP1L
luhur: J_TC: 1000.0°C (1828.0°F) K_TC: 1370.0°C (2498.0°F) T_TC: 400.0°C ( 752.0°F) R_TC: 1767.7°C (3214.0°F) S_TC: 1767.7°C (3214.0°F) PTDN: 850.0°C (1562.0°F) PTJS: 600.0°C (1112.0°F) |
537.8 °C
(1000.0 °F) |
Urang Sunda/W |
| 12 | FILT |
Nyaring damping time constant of PV |
0 0: 0 sec time constant
1 0.2: 0.2 sec time constant 2 0.5: 0.5 sec time constant 3 1: 1 sec time constant 4 2: 2 sec time constant 5 15: 5 sec time constant 6 10: 10 sec time constant 7 20: 20 sec time constant 8 30: 30 sec time constant 9 60: 60 sec time constant |
2 | Urang Sunda/W |
| 14 | PB | Band proporsional
nilai |
Handap: 0.0
Luhur: 500.0°C (900.0°F) |
10.0 °C
(18.0 °F) |
Urang Sunda/W |
| 15 | TI | Nilai waktos integral | Low: 0, High: 3600 sec | 60 | Urang Sunda/W |
| 16 | TD | Nilai waktos turunan | Low: 0, High: 360.0 sec | 30.0 | Urang Sunda/W |
| 11 | SHIF | PV shift (offset)
nilai |
Low: -200.0°C (-360.0°F) High: 200.0°C (360.0°F) | 0.0 °C
(0.0 °F) |
Urang Sunda/W |
| 68 | CICF | CIC filter switch | 0 OFF
1 DINA |
0 | R |
Output (oUT) Parameter
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés |
| 17 | OUT1 | Kaluaran 1 fungsi | 0 REVR: Reverse (heating) control action
1 dIRt: Direct (cooling) control action |
0 | Urang Sunda/W |
| 21 | CYC1 | Kaluaran 1 waktos siklus | Low: 0.1;
Luhur: 90.0 detik. |
18.0 | Urang Sunda/W |
| 18 | O1TY | Kaluaran 1 tipe sinyal | 0 RELY: kaluaran relay
1 SSrd: Kaluaran drive relay kaayaan padet 2 DC.MA: DC current 3 DC.Vo: DC voltage |
0 | Urang Sunda/W |
| 7 | OP1L | OP1 linear output low limit value | 0.0 ~ OP1H | 0.0 | Urang Sunda/W |
| 8 | OP1H | OP1 linear output
nilai wates luhur |
OP1L ~ 110.0 % | 100.0 | Urang Sunda/W |
| 19 | O1FT | Kaluaran 1 modeu transfer gagal | 0~1000: 0.0 ~ 100.0 % to continue output 1
control function if the sensor fails, or select OFF (0) or ON (1) for ON-OFF control |
0.0 | Urang Sunda/W |
| 22 | OFST | Offset value for P
kadali |
Handap: 0
Luhur: 100.0% |
25.0 | Urang Sunda/W |
| 20 | O1 HY | Output 1 ON-OFF
control hysteresis |
Handap: 0.1
High: 50.0 °C (90.0°F) |
0.5 °C
(0.9 °F) |
Urang Sunda/W |
| 23 | PL1L | MV1 power value
limit low |
Handap: 0
High: 50 % or PL1H |
0 | Urang Sunda/W |
| 24 | PL1H | MV2 power value limit high | Handap: PL1L
Luhur: 100% |
100 |
Urang Sunda/W |
| 25 | A1FN | Alarm 1 function for alarm 1 output | 0 NoNE: No alarm function
1 dE.HI: Deviation high alarm 2 dE.Lo: Deviation low alarm 3 db.HI: Deviation band out of band alarm 4 db.Lo: Deviation band in band alarm 5 PV.HI: Process value high alarm 6 PV.Lo: Process value low alarm |
1 |
Urang Sunda/W |
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés |
|
26 |
A1MD |
Alarm 1 operation mode |
0 NoRM: Normal alarm action
1 LtCH: Latching alarm action 2 HoLd: Hold alarm action 3 Lt.Ho: Latching & Hold action |
0 | Urang Sunda/W |
| 29 | A1HY | Alarm 1 Hysteresis control | Handap: 0.1
Luhur: 50.0°C (90.0°F) |
0.1 °C
(0.2 °F) |
Urang Sunda/W |
| 34 | A1DL | Alarm 1 delay | Low: 0; High: 5999 sec | 0 | Urang Sunda/W |
| 28 | A1FT | Alarm 1 failure trans- fer mode | 0 oFF: OFF if sensor fails
1 oN: ON if sensor fails |
1 | Urang Sunda/W |
| 1 | A1SP | Alarm 1 set point | A1FN=PVHI/PVLO
Low: SP1L High: SP1H |
100.0 °C
(212.0 °F) |
Urang Sunda/W |
| 13 | A1DV | Alarm 1 deviation value | A1FN=DEHI/DELO/DBHI/DBLO
Low: 0.0 High: 500.0°C (900.0°F) |
10.0 °C
(18.0 °F) |
Urang Sunda/W |
| 33 |
A2FN |
Alarm 2 function for alarm 2 output |
0 NoNE: No alarm function
1 dE.HI: Deviation high alarm 2 dE.Lo: Deviation low alarm 3 db.HI: Deviation band out of band alarm 4 db.Lo: Deviation band in band alarm 5 PV.HI: Process value high alarm 6 PV.Lo: Process value low alarm 7 COMM: RS485 |
2 |
Urang Sunda/W |
|
35 |
A2MD |
Alarm 2 operation mode |
0 NoRM: Normal alarm action
1 LtCH: Latching alarm action 2 HoLd: Hold alarm action 3 Lt.Ho: Latching & Hold action |
0 |
Urang Sunda/W |
| 36 | A2HY | Hysteresis control of alarm 2 | Handap: 0.1°C
Luhur: 50.0°C (90.0°F) |
0.1 °C
(0.2 °F) |
Urang Sunda/W |
| 38 | A2DL | Alarm 2 delay | Low: 0; High: 5999 sec | 0 | Urang Sunda/W |
| 37 | A2FT | Alarm 2 failure forced transfer mode | 0 oFF: Alarm output OFF if sensor fails
1 oN: Alarm output ON if sensor fails |
1 | Urang Sunda/W |
| 2 | A2SP | Alarm 2 set point | A2FN=PVHI/PVLO
Low: SP1L High: SP1H |
100.0 °C
(212.0 °F) |
Urang Sunda/W |
| 43 | A2DV | Alarm 2 deviation value | A2FN=DEHI/DELO/DBHI/DBLO
Low: 0.0 High: 500.0°C (900.0°F) |
10.0 °C
(18.0 °F) |
Urang Sunda/W |
Communication (CoMM) Parameter
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés |
| 39 | ADDR | Address assignment of digital komunikasi |
Handap: 1
Luhur: 255 |
1 | Urang Sunda/W |
| 40 | BAUD | Baud rate of digital communication | 0 2.4: 2.4 Kbits/s baud rate
1 4.8: 4.8 Kbits/s baud rate 2 9.6: 9.6 Kbits/s baud rate 3 14.4: 14.4 Kbits/s baud rate 4 19.2: 19.2 Kbits/s baud rate 5 28.8: 28.8 Kbits/s baud rate 6 38.4: 38.4 Kbits/s baud rate 7 57.6: 57.6 Kbits/s baud rate 8 115.2: 115.2 Kbits/s baud rate |
2 | Urang Sunda/W |
| 41 | DATA | Data bit count of dig- ital communication | 0 7bIt: 7 bit
1 8bIt: 8 bit |
1 | Urang Sunda/W |
| 42 | PARI | The parity bit of digi- tal communication | 0 EVEN: Even parity
1 odd: Odd parity 2 NoNE: No parity bit |
0 |
Urang Sunda/W |
Calibration Mode Parameter
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés |
| 52 | ADLO | mV calibration low
koefisien |
Handap: -1999
Luhur: 1999 |
—– |
Urang Sunda/W |
| 53 | ADHI | mV calibration high
koefisien |
Handap: -1999
Luhur: 1999 |
—– |
Urang Sunda/W |
| 54 | RTDL | RTD calibration low
koefisien |
Handap: -1999
Luhur: 1999 |
—– |
Urang Sunda/W |
| 55 | RTDH | RTD calibration high coefficient | Handap: -1999
Luhur: 1999 |
—– |
Urang Sunda/W |
| 56 | CJLO | Cold junction calibra-
tion low coefficient |
Handap: -5.00
Luhur: 40.00 |
—– |
Urang Sunda/W |
Parameter séjén
| Modbus | Parameter | Katerangan | Rentang | Default | Aksés |
| 57 | CJCT | Suhu simpang tiis | Handap: -4000
Luhur: 9000 |
—– | R |
| 58 | TANGGAL | titimangsa | Low: 0;
Luhur: 65535 |
—– | R |
| 59 | SRNO | Nomer séri | Low: 0;
Luhur: 65535 |
—– | R |
| 63 | CJCL | Cold junction low calibration
voltage |
Handap: 0
Luhur: 7552 |
—– | R |
| 69 | EROR | Kode kasalahan | Low: 0; High: 65535 | —– | R |
| 70 | MODÉ | Operation mode & alarm status | Handap: 0
Luhur: 65535 |
—– | R |
| 71 | PROG | Device version, firmware version | 67.XX | —– | R |
| 72 | KTP | Kode paréntah | Low: 0; High: 65535 | —– | Urang Sunda/W |
| 73 | JOB1 | Job code | Low: 0; High: 65535 | —– | Urang Sunda/W |
Kode Kasalahan
| Kasalahan Kodeu | tampilan
Lambang |
Katerangan & Alesan |
Koréksi Aksi |
| 10 | ER10 | Kasalahan komunikasi: kode fungsi goréng | Correct the communication software to meet the protocol
syarat |
| 11 | ER11 | Kasalahan komunikasi: ngadaptarkeun alamat di luar jangkauan | Do not issue an over-range address of the register to the slave |
| 14 | ER14 | Communication error: attempt to write a
read-only data |
Do not write read-only data or protected data to the slave |
| 15 | ER15 | Kasalahan komunikasi: nyerat nilai anu di luar jangkauan pikeun ngadaptar | Do not write an over-range data to the slave register |
| 26 | ATER | Auto-Tuning Error: Failed to perform Auto-Tuning function |
|
| 29 | EEPR | EEPROM teu tiasa ditulis leres | Balik deui ka produsén pikeun perbaikan. |
| 30 | CJER | santunan simpang tiis pikeun
Thermocouple malfungsi |
Balik deui ka produsén pikeun perbaikan. |
| 39 | SBER | Input sensor break | Replace the input sensor |
| 40 | ADER | A to D converter atawa komponén patali (s) gangguan | Return to the original manufacturer for repair. |
FAQ
How do I access the User Menu?
To access the User Menu, press the corresponding key on the controller.
How do I activate Auto-Tuning Mode?
To activate Auto-Tuning Mode, press and hold a specific key for 5 seconds.
How do I enter Manual Control Mode? To enter Manual Control Mode, press the designated key for 3 seconds. How do I perform calibration? To calibrate a parameter, press and hold the ENTER key for 5 seconds during the calibration procedure.
To enter Manual Control Mode, press the designated key for 3 seconds.
How do I perform calibration?
To calibrate a parameter, press and hold the ENTER key for 5 seconds during the calibration procedure.
Dokumén / Sumberdaya
![]() |
Brainchild E62 PID Temperature Controller [pdf] Instruksi Manual E62, QS0E620C, E62 PID Temperature Controller, E62, PID Temperature Controller, Temperature Controller, Controller |