DELTA DVP04PT-S PLC Analog Input Output Module
spésifikasi
- Modél: DVP04 / 06PT-S
- Input: 4/6 titik RTDs
- Kaluaran: 16-bit sinyal digital
- Pamasangan: Kabinét kontrol bébas tina lebu, kalembaban, shock listrik, sareng geter
- Ukuran: 90.00mm x 60.00mm x 25.20mm
- Alat tipe kabuka
- Unit kakuatan misah
Parentah Pamakéan Produk
Pedoman Instalasi
- Pastikeun kabinét kontrol bébas tina lebu hawa, kalembaban, shock listrik, sareng geter.
- Paké safeguard pikeun nyegah aksés nu teu sah atawa kacilakaan.
- Hindarkeun nyambungkeun kakuatan AC ka terminal I/O mana waé.
Nguatkeun Up
- Mariksa dua kali sadaya kabel samemeh mareuman alat.
- Hindarkeun noel terminal naon waé pikeun samenit saatos pegatkeun sambungan alat.
- Bener taneuh terminal pikeun nyegah gangguan éléktromagnétik.
Wiring éksternal
- Turutan diagram wiring disadiakeun dina manual pikeun sambungan ditangtoskeun.
- Paké kabel shielded pikeun integritas sinyal hadé.
- Tetep kawat sapendek mungkin pikeun ngurangan gangguan noise.
Bubuka
Hatur nuhun pikeun milih Delta DVP runtuyan PLC. DVP04 / 06PT-S tiasa nampi 4/6 titik RTD sareng ngarobih kana sinyal digital 16-bit. Ngaliwatan FROM / TO parentah dina DVP Slim runtuyan program MPU, data bisa dibaca tur ditulis. Aya loba 16-bit kontrol registers (CR) dina modul. Unit kakuatan dipisahkeun sareng ukuranana alit sareng gampang dipasang.
DVP04 / 06PT-S mangrupikeun alat OPEN-TYPE. Eta kudu dipasang dina kabinét kontrol bébas tina lebu airborne, kalembaban, shock listrik sarta Geter. Pikeun nyegah staf non-pangropéa tina operasi DVP04 / 06PT-S, atawa pikeun nyegah kacilakaan tina ngaruksak DVP04 / 06PT-S, kabinét kontrol nu DVP04 / 06PT-S dipasang kudu dilengkepan safeguard a. Pikeun exampLe, kabinét kontrol dimana DVP04 / 06PT-S dipasang tiasa dikonci ku alat atanapi konci khusus.
Ulah nyambungkeun kakuatan AC ka salah sahiji terminal I / O, disebutkeun karuksakan serius bisa lumangsung. Mangga parios sadayana wiring deui sateuacan DVP04/06PT-S diaktipkeun. Saatos DVP04 / 06PT-S dipegatkeun, Ulah noél terminal wae dina hiji menit. Pastikeun yén terminal taneuh on DVP04 / 06PT-S ieu leres grounded guna nyegah gangguan éléktromagnétik.
Produk Profile & Diménsi
1. Indikator status (POWER, RUN and ERROR) | 2. Ngaran modél | 3. DIN rail klip |
4. I / O terminal | 5. I / O indikator titik | 6. Lubang pasang |
7. labél spésifikasi | 8. I / O port sambungan modul | 9. I / O klip modul |
10. Rel DIN (35mm) | 11. I / O klip modul | 12. palabuhan komunikasi RS-485 (DVP04PT-S) |
13. port sambungan kakuatan (DVP04PT-S) |
14. I / O port sambungan |
Wiring
I / O Layout Terminal
Wiring éksternal
Catetan
- Anggo ukur kawat anu dipak ku sénsor suhu pikeun input analog sareng misahkeun tina saluran listrik sanés atanapi kawat naon waé anu tiasa nyababkeun sora.
- 3-kawat sensor RTD nyadiakeun loop santunan nu bisa dipaké pikeun subtract lalawanan kawat bari 2-kawat sensor RTD teu boga mékanisme pikeun ngimbangan. Anggo kabel (3-kabel) anu panjangna sami (kurang ti 200 m) sareng résistansi kawat kirang ti 20 ohm.
- Lamun aya noise, mangga sambungkeun kabel shielded ka titik sistem bumi, lajeng taneuh titik sistem bumi atawa sambungkeun ka kotak distribusi.
- Punten jaga kabel sasingkat-gancang nalika nyambungkeun modul ka alat anu suhuna badé diukur, sareng jaga kabel listrik anu dianggo sajauh-jauhna tina kabel anu nyambung ka beban sabisa-bisa pikeun nyegah gangguan bising.
- Mangga sambungkeun
dina modul catu daya jeung
dina modul suhu ka taneuh sistem, lajeng taneuh sistem taneuh atawa sambungkeun taneuh sistem ka kotak distribution.
spésifikasi
Spésifikasi listrik
Max. konsumsi kakuatan dipeunteun | 2W |
Operasi / neundeun | Operasi: 0 ° C ~ 55 ° C (temp.), 5 ~ 95% (kalembaban), tingkat polusi 2
Panyimpenan: -25 ° C ~ 70 ° C (temp.), 5 ~ 95% (kalembaban) |
Geter / résistansi shock | Standar internasional: IEC61131-2, IEC 68-2-6 (TEST Fc)/ IEC61131-2 & IEC 68-2-27 (TEST Ea) |
Sambungan runtuyan ka DVP- PLC MPU |
The modul nu wilanganana ti 0 nepi ka 7 otomatis ku jarak maranéhanana ti MPU. No.0 nu pangdeukeutna ka MPU jeung No.7 nu pangjauhna. maksimal
8 modul diidinan nyambung ka MPU sareng moal ngeusian titik I / O digital. |
Spésifikasi fungsional
DVP04/06PT-S | Celsius (°C) | Fahrenheit (°F) |
Saluran input analog | 4/6 saluran per modul | |
Jenis sénsor | 2-kawat/3-kawat Pt100 / Pt1000 3850 PPM/°C (DIN 43760 JIS C1604-1989)
/ Ni100 / Ni1000 / LG-Ni1000 / Cu100 / Cu50/ 0~300Ω/ 0~3000Ω |
|
éksitasi ayeuna | 1.53mA / 204.8uA | |
rentang input suhu | Mangga tingal kurva karakteristik suhu/nilai digital. | |
rentang konversi digital | Mangga tingal kurva karakteristik suhu/nilai digital. | |
Resolusi | 0.1°C | 0.18°F |
Gemblengna akurasi | ± 0.6% tina skala pinuh salila 0 ~ 55°C (32 ~ 131°F) | |
waktos respon | DVP04PT-S: 200ms / saluran; DVP06PT-S: 160 / mdet / saluran | |
Métode isolasi
(antara sirkuit digital sareng analog) |
Henteu aya isolasi antara saluran.
500VDC antara sirkuit digital/analog jeung Ground 500VDC antara sirkuit analog jeung sirkuit digital 500VDC antara 24VDC jeung Ground |
|
format data digital | 2 urang pelengkap 16-bit | |
Fungsi rata-rata | Leres (DVP04PT-S: CR#2 ~ CR#5 / DVP06PT-S: CR#2) | |
Fungsi diagnostik diri | Unggal saluran boga fungsi deteksi wates luhur/handap. | |
RS-485 Modeu Komunikasi |
Dirojong, kaasup mode ASCII / RTU. Format komunikasi standar: 9600, 7, E, 1, ASCII; tingal CR#32 pikeun detil ngeunaan format komunikasi.
Catetan1: RS-485 teu tiasa dianggo nalika dihubungkeun sareng PLC séri CPU. Catetan2: Tingali Slim Type Special Module Communications dina lampiran E tina manual programming DVP pikeun detil nu langkung lengkep ihwal setelan komunikasi RS-485. |
* 1: Unit suhu bakal dipintonkeun salaku 0.1 ° C / 0.1 ° F. Upami unit suhu disetel janten Fahrenheit, tempat desimal kadua moal ditingalikeun.
Control ngadaptar
CR# | Alamat | Diteuteup | Atribut | Ngadaptar eusi | Katerangan | |||
#0 | H'4064 | O | R | Ngaran modél
(Disetél ku sistem) |
Kode modél DVP04PT-S = H'8A
Kode modél DVP06PT-S = H'CA |
|||
#1 |
H'4065 |
X |
Urang Sunda/W |
CH1 ~ CH4 Setélan Mode |
b15~12 | b11~8 | b7~4 | b3~0 |
CH4 | CH3 | CH2 | CH1 | |||||
Candak mode CH1 (b3,b2,b1,b0) pikeun example.
1. (0,0,0,0): Pt100 (standar) 2. (0,0,0,1): Ni100 3. (0,0,1,0): Pt1000 4. (0,0,1,1): Ni1000 5. (0,1,0,0): LG-Ni1000 6. (0,1,0,1): Cu100 7. (0,1,1,0): Cu50 8. (0,1,1,1): 0~300 Ω 9. (1,0,0,0): 0~3000 Ω 10. (1,1,1,1) Saluran ieu ditumpurkeun. modeu 8 jeung 9 ngan sadia pikeun DVP04PT-S V4.16 atanapi engké na DVP06PT-S V4.12 atanapi engké. |
||||||||
#2 |
H'4066 |
O |
Urang Sunda/W |
DVP04PT-S: Jumlah rata-rata CH1 |
Jumlah sapotong bacaan dipaké pikeun itungan suhu "rata" dina CH1.
rentang setelan: K1 ~ K20. Setélan standar nyaéta K10. |
|||
— |
DVP06PT-S: Jumlah rata-rata CH1~CH6 |
Jumlah sapotong bacaan dipaké pikeun itungan suhu "rata" dina CH1 ~ 6.
rentang setelan: K1 ~ K20. Setélan standar nyaéta K10. |
||||||
#3 |
H'4067 |
O |
H'4067 |
DVP04PT-S: Jumlah rata-rata CH2 |
Jumlah sapotong bacaan dipaké pikeun itungan suhu "rata" dina CH2.
rentang setelan: K1 ~ K20. Setélan standar nyaéta K10. |
|||
#4 |
H'4068 |
O |
H'4068 |
DVP04PT-S: Jumlah rata-rata CH3 |
Jumlah sapotong bacaan dipaké pikeun itungan suhu "rata" dina CH3.
rentang setelan: K1 ~ K20. Setélan standar nyaéta K10. |
|||
#5 |
H'4069 |
O |
H'4069 |
DVP04PT-S: Jumlah rata-rata CH4 |
Jumlah sapotong bacaan dipaké pikeun itungan suhu "rata" dina CH4.
rentang setelan: K1 ~ K20. |
#6 | H'406A | X | R | CH1 darajat rata-rata | DVP04PT-S:
Gelar rata pikeun CH1 ~ 4 DVP06PT-S: Gelar rata pikeun CH1 ~ 6 Unit: 0.1°C, 0.01 Ω (0~300 Ω), 0.1 Ω (0~3000 Ω) |
||||
#7 | H'406B | X | R | CH2 darajat rata-rata | |||||
#8 | H'406C | X | R | CH3 darajat rata-rata | |||||
#9 | H'406D | X | R | CH4 darajat rata-rata | |||||
#10 | — | X | R | CH5 darajat rata-rata | |||||
#11 | — | X | R | CH6 darajat rata-rata | |||||
#12 | H'4070 | X | R | CH1 darajat rata-rata | DVP04PT-S:
Gelar rata pikeun CH1 ~ 4 DVP06PT-S: Gelar rata-rata pikeun CH1 ~ 6 Unit: 0.1°F, 0.01 Ω (0~300 Ω), 0.1 Ω (0~3000 Ω) |
||||
#13 | H'4071 | X | R | CH2 darajat rata-rata | |||||
#14 | H'4072 | X | R | CH3 darajat rata-rata | |||||
#15 | H'4073 | X | R | CH4 darajat rata-rata | |||||
#16 | — | X | R | CH5 darajat rata-rata | |||||
#17 | — | X | R | CH6 darajat rata-rata | |||||
#18 | H'4076 | X | R | Suhu ayeuna. tina CH1 | DVP04PT-S:
Suhu ayeuna CH 1~4 DVP06PT-S: Suhu ayeuna CH1~6 Unit: 0.1°C, 0.01 Ω (0~300 Ω), 0.1 Ω (0~3000 Ω) |
||||
#19 | H'4077 | X | R | Suhu ayeuna. tina CH2 | |||||
#20 | H'4078 | X | R | Suhu ayeuna. tina CH3 | |||||
#21 | H'4079 | X | R | Suhu ayeuna. tina CH4 | |||||
#22 | — | X | R | Suhu ayeuna. tina CH5 | |||||
#23 | — | X | R | Suhu ayeuna. tina CH6 | |||||
#24 | H'407C | X | R | Suhu ayeuna. tina CH1 |
DVP04PT-S: Suhu ayeuna CH 1~4 DVP06PT-S: Suhu ayeuna CH 1~6 Unit: 0.1°F, 0.01 Ω (0~300 Ω), 0.1 Ω (0~3000 Ω) |
||||
#25 | H'407D | X | R | Suhu ayeuna. tina CH2 | |||||
#26 | H'407E | X | R | Suhu ayeuna. tina CH3 | |||||
#27 | H'407F | X | R | Suhu ayeuna. tina CH4 | |||||
#28 | — | X | R | Suhu ayeuna. tina CH5 | |||||
#29 | — | X | R | Suhu ayeuna. tina CH6 | |||||
#29 |
H'4081 |
X |
Urang Sunda/W |
DVP04PT-S: Setélan modeu PID |
Atur H'5678 salaku mode PID sarta nilai séjén salaku mode normal
Nilai standar nyaéta H'0000. |
||||
#30 |
H'4082 |
X |
R |
Status kasalahan |
Data register nyimpen status kasalahan. Tingal bagan kode kasalahan pikeun detil. | ||||
#31 |
H'4083 |
O |
Urang Sunda/W |
DVP04PT-S:
Setélan alamat komunikasi |
Nyetél alamat komunikasi RS-485; rentang setelan: 01 ~ 254.
Standar: K1 |
||||
— |
X |
Urang Sunda/W |
DVP06PT-S:
CH5 ~ CH6 Setélan Mode |
Modeu CH5: b0 ~ b3 Modeu CH6: b4 ~ b7
Tempo CR # 1 pikeun rujukan |
|||||
32 |
H'4084 |
O |
Urang Sunda/W |
DVP04PT-S: Setélan format komunikasi |
Pikeun laju baud, setélan nyaéta 4,800/9,600/19,200/38,400/57,600/115,200 bps.
Format komunikasi: ASCII: 7,E,1/7,O,1/8,E,1/8,O,1 / 8,N,1 RTU: 8,E,1 / 8,O,1 / 8,N,1 Standar pabrik: ASCII,9600,7,E,1 (CR#32=H'0002) Tingal ka ※CR#32 setélan format komunikasi dina tungtung tabel ieu pikeun inpo nu leuwih lengkep. |
||||
— |
X |
Urang Sunda/W |
DVP06PT-S: CH5 ~ CH6 Kasalahan setélan indikator LED |
b15~12 | b11~9 | b8~6 | b5~3 | b2~0 | |
ERR
LED |
ditangtayungan | CH6 | CH5 | ||||||
b12 ~ 13 pakait jeung CH5 ~ 6, nalika bit ON, skala ngaleuwihan rentang, sarta indikator Kasalahan LED flashes. | |||||||||
#33 |
H'4085 |
O |
Urang Sunda/W |
DVP04PT-S: CH1 ~ CH4
Reset ka setelan standar Jeung Kasalahan indikator LED setelan |
|||||
b15~12 | b11~9 | b8~6 | b5~3 | b2~0 | |||||
ERR
LED |
CH4 | CH3 | CH2 | CH1 | |||||
Upami b2~b0 disetel ka 100, sadaya nilai pangaturan CH1 bakal direset |
— |
X |
Urang Sunda/W |
DVP06PT-S: CH1 ~ CH4 Reset ka setelan standar Jeung CH1 ~ CH4 Kasalahan LED indikator setelan |
ka standar. Pikeun ngareset sadaya saluran ka standar, setel b11 ~ 0 ka H'924 (DVP04PT-S ngadukung reset tunggal sareng sadaya saluran; DVP06PT- S ngadukung sadaya saluran reset wungkul). b12~15 pakait jeung CH1~4, nalika bit ON, skala ngaleuwihan
rentang, jeung kasalahan LED indikator flashes. |
|
#34 | H'4086 | O | R | Vérsi firmware | Vérsi tampilan dina héksadesimal. ex:
H'010A = Vérsi 1.0A |
# 35 ~ # 48 Pikeun pamakéan sistem | |||||
Simbol: O hartina kancing. (Dirojong ku RS485, tapi henteu ngadukung nalika nyambungkeun ka MPU.)
X hartina teu kait. R hartina bisa maca data ku ngagunakeun instruksi FROM atawa RS-485. W hartina bisa nulis data ku ngagunakeun instruksi TO atawa RS-485. |
- Ditambahkeun fungsi RESET ngan pikeun modul 04PT-S kalawan firmware V4.16 atanapi engké na teu sadia pikeun 06PT-S. Sambungkeun input kakuatan modul 24 VDC jeung nulis H'4352 kana CR # 0 lajeng mareuman kakuatan tur on deui; kabéh parameter dina modul, kaasup parameter komunikasi disimpen deui ka standar pabrik.
- Upami anjeun hoyong nganggo alamat Modbus dina format desimal, anjeun tiasa nransferkeun register héksadesimal kana format desimal teras tambahkeun hiji supados janten alamat ngadaptar Modbus desimal. Pikeun example mindahkeun alamat "H'4064" tina CR # 0 dina format hexadecimal kana format decimal, mun boga hasilna 16484 lajeng nambahkeun hiji eta, anjeun boga 16485, alamat Modbus dina format decimal.
- Setélan format komunikasi CR # 32: pikeun modul DVP04PT-S kalawan firmware V4.14 atawa versi saméméhna, b11 ~ b8 pilihan format data teu sadia. Pikeun mode ASCII, formatna dilereskeun kana 7, E, 1 (H'00XX) sareng pikeun mode RTU, formatna dilereskeun kana 8, E, 1 (H'C0xx/H'80xx). Pikeun modul jeung firmware V4.15 atanapi engké, tingal tabel di handap pikeun setups. Catet yén kode aslina H'C0XX / H'80XX bakal ditempo salaku RTU, 8, E, 1 pikeun modul jeung firmware V4.15 atanapi engké.
b15 ~ b12 | b11 ~ b8 | b7 ~ b0 | |||
ASCII / RTU, tukeur bait low jeung luhur kode CRC dipariksa |
Format data |
Laju baud |
|||
Katerangan | |||||
H'0 | ASCII | H'0 | 7,E,1*1 | H'01 | 4800 bps |
H'8 |
RTU,
entong tukeur bait rendah sareng luhur kode cek CRC |
H'1 | 8,E,1 | H'02 | 9600 bps |
H'2 | ditangtayungan | H'04 | 19200 bps | ||
H'C |
RTU,
tukeur bait lemah sareng luhur kode cek CRC |
H'3 | 8,N,1 | H'08 | 38400 bps |
H'4 | 7,O,1*1 | H'10 | 57600 bps | ||
H'5 | 8.O,1 | H'20 | 115200 bps |
Catetan *1: Ieu ngan sadia pikeun format ASCII.
Misal: Tulis H'C310 kana CR # 32 pikeun hasil tina RTU, tukeur bait lemah sareng luhur kode cék CRC, 8,N,1 sarta laju baud dina 57600 bps.
- Kodeu fungsi RS-485: 03'H nyaéta pikeun maca data tina registers. 06'H nyaéta pikeun nulis kecap data pikeun ngadaptar. 10'H nyaéta pikeun nulis sababaraha kecap data pikeun ngadaptar.
- CR # 30 nyaéta register kode kasalahan.
- Catetan: Unggal kode kasalahan bakal boga bit pakait jeung kudu dirobah jadi angka binér 16-bit (Bit0~15). Dua atawa leuwih kasalahan bisa lumangsung dina waktos anu sareng. Tingali kana bagan di handap ieu:
Jumlah bit | 0 | 1 | 2 | 3 |
Katerangan |
Sumber kakuatan abnormal | Kontakna teu nyambung ka nanaon. |
Ditangtayungan |
Ditangtayungan |
Jumlah bit | 4 | 5 | 6 | 7 |
Katerangan | Ditangtayungan | Ditangtayungan | kasalahan angka rata | Kasalahan instruksi |
Jumlah bit | 8 | 9 | 10 | 11 |
Katerangan | CH1 Konversi abnormal | CH2 Konversi abnormal | CH3 Konversi abnormal | CH4 Konversi abnormal |
Jumlah bit | 12 | 13 | 14 | 15 |
Katerangan | CH5 Konversi abnormal | CH6 Konversi abnormal | Ditangtayungan | Ditangtayungan |
- Suhu/Nilai Digital Kurva Karakteristik
Modeu pangukuran suhu Celsius (Fahrenheit):
Sénsor | Rentang suhu | rentang konversi nilai digital | ||
°C (Min./Max.) | ° F (Min./Max.) | °C (Min./Max.) | ° F (Min./Max.) | |
Pt100 | -180 ~ 800°C | -292 ~ 1,472°F | K-1,800 ~ K8,000 | K-2,920 ~ K14,720 |
Ni100 | -80 ~ 170°C | -112 ~ 338°F | K-800 ~ K1,700 | K-1,120 ~ K3,380 |
Pt1000 | -180 ~ 800°C | -292 ~ 1,472°F | K-1,800 ~ K8,000 | K-2,920 ~ K14,720 |
Ni1000 | -80 ~ 170°C | -112 ~ 338°F | K-800 ~ K1,700 | K-1,120 ~ K3,380 |
LG-Ni1000 | -60 ~ 200°C | -76 ~ 392°F | K-600 ~ K2,000 | K-760 ~ K3,920 |
Ku100 | -50 ~ 150°C | -58 ~ 302°F | K-500 ~ K1,500 | K-580 ~ K3,020 |
Ku50 | -50 ~ 150°C | -58 ~ 302°F | K-500 ~ K1,500 | K-580 ~ K3,020 |
Sénsor | Input résistor rentang | rentang konversi nilai digital | ||
0~300Ω | 0Ω ~ 320Ω | K0 ~ 32000 | 0~300Ω | 0Ω ~ 320Ω |
0~3000Ω | 0Ω ~ 3200Ω | K0 ~ 32000 | 0~3000Ω | 0Ω ~ 3200Ω |
- Nalika CR # 29 disetel ka H'5678, CR # 0 ~ CR # 34 bisa dipaké pikeun setelan PID kalawan versi DVP04PT-S V3.08 na luhur.
FAQ
- Q: Dupi abdi tiasa nyambungkeun kakuatan AC ka salah sahiji terminal I / O?
- A: Henteu, nyambungkeun kakuatan AC ka terminal I/O mana waé tiasa nyababkeun karusakan anu serius. Salawasna pariksa dua kali wiring saméméh powering up.
- Q: Kumaha carana abdi kedah nanganan alat sanggeus disconnection?
- A: Saatos pegatkeun sambungan alat, ulah noel terminal mana wae salila sahenteuna hiji menit pikeun mastikeun kaamanan.
- Q: Naon anu kudu dilakukeun pikeun nyegah gangguan éléktromagnétik?
- A: Pastikeun yén terminal taneuh dina alat tos leres grounded pikeun nyegah gangguan éléktromagnétik.
Dokumén / Sumberdaya
![]() |