ERP POWER PLUS LIGHT PLS Series Optional Auxiliary Output

Parentah Pamakéan Produk
- Pastikeun input voltage aya dina rentang 120 – 277 Vac.
- Connect the appropriate wiring according to the provided wiring diagram.
- Secure the LED driver in a suitable location with proper ventilation to prevent overheating.
- Use the ERP LED Driver Configuration Tool (ERP GUI) to program the output current as needed.
- Ensure programmed values are within specified limits for optimal performance.
- To dim the LEDs connected to the driver, use a compatible 0-10 V dimmer.
- Adjust the dimming level between 1% and 100% as desired.
- If utilizing the optional auxiliary output, connect the auxiliary devices following the provided guidelines for proper functionality.
| Masukan Voltage | Max. Daya Kaluaran | Efisiensi | Max. Suhu Kasus | THD | Faktor kakuatan | Métode Dimming | Rentang Dimming | Mimitian-up Time |
| 120 – 277 Vac | 85 W | up to 87% typical | 90°C (measured at the hot spot) | < 20%
@ max load |
> 0.9 | Programmable 0 – 10 V | 1 – 100% | 300ms biasa |

FITUR
- Meets IEEE 1789-2015 “no impact” recommended practices for flicker
- UL8750 Class P, Class 2 power supply
- Programmable dim-to-off
- Optional programmable auxiliary output
- Synchronized start-up: 20 ms
- Lifetime: 50,000 hours @ Tc ≤ 75℃
- 90℃ maximum case hot spot temperature
- Perlindungan surge:
- IEC61000-4-5: 6 kV line to line/6 kV line to earth
- 2.5 kV ring wave: ANSI/IEEE c62.41.1-2002 & c62.41.2-2002 category A
- Complies with ENERGY STAR®, DLC (DesignLight Consortium®), and CA Title 24 technical requirements
Diagram Wiring

PEMROGRAMAN
- Audio jack and cradle programming
- Current: see page 2 for current range
- Fully programmable and selectable 0-10V dimming profiles: Non-linear with dim-to-off, Logarithmic, Non-linear without dim-to-off.
- Data log read: SKU, S/N, lot code, hours of operation, FW rev., power cycles
APLIKASI
- Commercial & residential lighting
- cahaya Arsitéktur
- Cahaya jero rohangan
INFORMASI ORDER
| Nomer Bagian | Masukan Voltage (Vac) | Max Daya Kaluaran
(W) |
Kaluaran (mA)(1) | Default Programmed Current
(mA) |
Vout Min. (Vdc) | Vout Nom. (Vdc) | Vout Max. (Vdc)(2) | Open Loop (No Load) Voltage (Vdc) |
Catetan |
| Nepi ka 20W | |||||||||
| PLS-A20W-07-55-TZ | 120 – 277 | 20 | 100 nepi ka 700 | 350 | 10 | 49.5 | 55 | 60 | |
| PLS-A20W-07-55-TXZ | 120 – 277 | 20 | 100 nepi ka 700 | 350 | 10 | 49.5 | 55 | 60 | Kaluaran Bantu |
| 21 nepi ka 30W | |||||||||
| PLS-A30W-10-55-TZ | 120 – 277 | 30 | 275 nepi ka 1050 | 700 | 10 | 49.5 | 55 | 60 | |
| PLS-A30W-10-55-TXZ | 120 – 277 | 30 | 275 nepi ka 1050 | 700 | 10 | 49.5 | 55 | 60 | Kaluaran Bantu |
| 31 nepi ka 50W | |||||||||
| PLS-A50W-14-55-TZ | 120 – 277 | 50 | 500 nepi ka 1400 | 1050 | 10 | 49.5 | 55 | 60 | |
| PLS-A50W-14-55-TXZ | 120 – 277 | 50 | 500 nepi ka 1400 | 1050 | 10 | 49.5 | 55 | 60 | Kaluaran Bantu |
| 51 nepi ka 65W | |||||||||
| PLS-A65W-18-55-TZ | 120 – 277 | 65 | 600 nepi ka 1800 | 1200 | 10 | 49.5 | 55 | 60 | |
| PLS-A65W-18-55-TXZ | 120 – 277 | 65 | 600 nepi ka 1800 | 1200 | 10 | 49.5 | 55 | 60 | Kaluaran Bantu |
| 66 nepi ka 85W | |||||||||
| PLS-A85W-23-55-TXZ | 120 – 277 | 85 | 700 nepi ka 2300 | 1400 | 10 | 49.5 | 55 | 60 | Kaluaran Bantu |
Catetan
- The ERP LED Driver Configuration Tool (ERP GUI) allows programming of the output current to values below the minimum limits specified in the table above. However, when the programmed output current is set below these minimum thresholds, the LED driver’s Total Harmonic Distortion (THD) and Power Factor (PF) may not meet the values defined in the INPUT SPECIFICATION section of this datasheet. For proper operation, please also refer to the OPERATING ENVELOPE for each part number, which defines the permissible ranges of output current and output voltage where THD and PF compliance is maintained.
- Maju voltage (Vf) of the LED load should not exceed Vout Max. of the driver under worst case field operating conditions which are the Vf max. of the LED load under lowest temperature and highest forward current conditions. As a general design guideline, the nominal LED load Vf measured at the operating current and at room temperature should be ≤ Vout Nom. of the driver.
AKSESORI
Catetan:
- Please order the programming cable using part number PROG-JACK-USB.
- The optional programming cradle can be ordered using part number PROG-CRADLE
Kabel Pemrograman
- Part number: PROG-JACK-USB

Programming Cradle
- Part number: PROG-CRADLE

OPERATING ENVELOPES

SPESIFIKASI
INPUT SPECIFICATION (@25℃ ambient temperature)
| Hijian | Minimal | has | maksimal | Catetan | |
| Masukan Voltage Range (Vin) | Vac | 108 | 120, 277 | 305 | The rated output current for each model is achieved at Vin≥108 Vac, and at Vin≥249 Vac.
At nominal load |
| Input rentang Frékuénsi | Hz | 47 | 50/60 | 63 | |
| Input Current (Iin) | A | 0.7 A @ 120 Vac
0.35 A @ 277 Vac |
|||
| Faktor Kakuatan (PF) | 0.9 | > 0.9 | At nominal input voltage (120 & 277 Vac) and no dimmer
From 100% to 50% of output power |
||
| Inrush Ayeuna | A | Meets NEMA-410 requirements | At any point on the sine wave and 25°C | ||
| Leakage Ayeuna |
mA |
0.4 mA @ 120 Vac
0.75 mA @ 277 Vac |
Measured per IEC60950-1 |
||
| Input Harmonics | Complies with IEC61000-3-2 for Class C equipment | ||||
| Total Harmonics Distortion (THD) | 20% | At nominal input voltage (120 & 277 Vac)
From 100% to 50% of output power Complies with DLC (Design Light Consortium) technical requirements |
|||
| Efisiensi | % | – | nepi ka 87% | – | Measured with nominal input voltage, a full sinusoidal wave form and without dimmer attached. |
| Isolasi | The AC input to the main DC output is isolated. | ||||
MAIN OUTPUT SPECIFICATION (@25℃ ambient temperature)
| Hijian | Minimal | has | maksimal | Catetan | |
| Kaluaran Voltage (Vout) | Vdc | See ordering information for details | |||
| Output Current (Iout) | mA | By steps of 1 mA
See ordering information for details Kaluaran voltage and current combination cannot exceed max power output. See page 3 for operating window The rated output current for each model is achieved at Vin≥108 Vac & Vin≥249 Vac. |
|||
| Output Current Regulation | % | -3 | ± 2 | 3 | At nominal AC line voltage (120 & 277 Vac)
Includes load and current set point variations |
| Output Current Overshoot | % | – | – | 20 | The driver does not operate outside of the regulation requirements for more than 500 ms during power on with nominal LED load and without dimmer. |
| Ripple Ayeuna | ≤ 20% of rated output current for each model | Measured at nominal LED voltage and nominal input voltage without dimming
Calculated in accordance with the IES Lighting Handbook, 9th edition Meets IEEE 1789-2015 “no impact” recommended practices for flicker |
|||
| Rentang Dimming | % | 1 | 100 | The dimming range is dependent on each specific dimmer. It may not be able to achieve 1% dimming with some dimmers.
When testing, if light is measured, dimming range is based on light output. If no light is measured, dimming range is based on percentage tina arus kaluaran. Dimming performance is optimal when the driver is operated at its nominal output voltage matching the LED nominal Vf (forward voltage). Dimming performance may vary when the driver is operated near its minimum output voltage. |
|
| Mimitian-up Time | ms | 300 | 500 | Without any dimmer attached, and at nominal input voltages and nominal load
Synchronized start-up of 20 ms when multiple drivers on same circuit Measured from application of AC line voltage to continuous light output Complies with ENERGY STAR® luminaire specification and CA Title 24 |
|
| Isolasi | The main DC output is isolated from the AC input and meets UL8750 supplement SF requirements. | ||||
AUXILIARY OUTPUT SPECIFICATION “-TXZ” MODELS ONLY (@25℃ ambient temperature)
| Hijian | Minimal | has | maksimal | Catetan | |
| Auxilliary Output Voltage | Vdc | 9.5 | 12 | 24 | Default value is 12 V
+/-10% voltage régulasi Configurable through programming in 0.5 V increments |
| Auxilliary Output Current | mA | 110 mA | Maximum power output is 1.2 W
+/-10% current regulation |
DIMMING CONTROL
DIMMING CONTROL (@25℃ ambient temperature)
- In the PLS-A series, several 0-10V dimming profiles can be selected, such as a logarithmic profile, a non-linear profile with 1% minimum dimming, a non-linear profile with 10% minimum dimming, and an optional dim-to-off function.
- Furthermore, every point in the non-linear dimming profile can be programmed using the ERP Power LED Configuration software (ERP GUI).
- By default, the non-linear profile with 1% minimum dimming and NO dim-to-off is pre-loaded in the PLS-A series.
| Hijian | Minimal | has | maksimal | Catetan | |
| +Dim Signal, -Dim Signal | The PLS series operates only with 0-10 V dimmers that sink current. The method to dim the output current of the driver is done via the +Dim/-Dim Signal pins. The +Dim/-Dim signal pins can be used to adjust the output setting via a standard commercial wall dimmer, an external control voltage source (0 to 10 Vdc), or a variable resistor when using the recommended number of LEDs. The dimming input permits 1% to 100% dimming. | ||||
| Dimming Profile | 100% of output current between 10 V and 8 V, Linear between 8 V and 1 V, 1% of the output current below 1 V. | ||||
| Rentang Dimming | % | 1 | 100 | When testing, if light is measured, the dimming range is based on light output. If no light is measured, the dimming range is based on the percentage tina arus kaluaran. | |
| High Level Voltage – A | V | 8.0 | 8.1 | Pangluhurna voltage available with programming: 8.5 V | |
| Low Level Voltage – B | V | 0.9 | 1.0 | Panghandapna voltage available with programming: 0.1V | |
| Dim to Off – C | V | 0.6 | 0.7 | 0.8 | |
| Dim to Off Hysteresis – D | V | +0.2 | |||
| Current Supplied by the
+Dim Signal Pin |
mA | 0.5 | |||
| Dimming Voltage Sensing Tolerance | mV | 100 | The tolerance of the difference between the 0-10 V signal supplied by the dimmer and sensed by the driver. | ||
| Output Current Tolerance While Being Dimmed | % | ± 8 | In the linear region of the dimming curve (between points A and B in Figure 1). | ||
| Minimum Dimming Tolerance | % | 0.6 | 1 | 2 | At point B, in Figure 1 |
| Isolasi | The 0-10 V circuit is isolated from the AC input and meets UL8750 supplement SF requirements. | ||||

SYARAT LINGKUNGAN
| Hijian | Minimal | has | maksimal | Catetan | |
| Operating Ambient Temperature (Ta) | °C | -20 | 50 | 50°C is the non-derated temperature (Refer to section 11 ‘Output power protection’.) | |
| Maximum Case Temperature (Tc) | °C | +90 | Case temperature measured at the hot spot Ÿtc (see label in section 23) | ||
| Suhu Panyimpenan | °C | -40 | +85 | ||
| Kalembaban | % | 5 | – | 95 | Non-condensing |
| Niiskeun | Konveksi tiis | ||||
| Noise Akustik | dBA | 24 | Measured at a distance of 1 foot, without a dimmer | ||
| Mechanical Shock Protection | per EN60068-2-27 | ||||
| Perlindungan Geter | per EN60068-2-6 & EN60068-2-64 | ||||
| MTBF | > 200,000 hours when operated at nominal input and output conditions, and at Tc ≤ 75°C | ||||
| Saumur hirup | 50,000 hours at Tc ≤ 75°C maximum case hot spot temperature (see hot spottc on label in section 23) | ||||
| Garansi | 5 years. Users must utilize proper thermal management techniques to ensure proper thermal conductivity
between the driver and heat sink. The use of double-sided tape to mount the driver voids the warranty. |
||||
EMC COMPLIANCE, SAFETY, AND ENVIRONMENTAL APPROVALS
| EMC minuhan | |||
| Dilaksanakeun sarta Radiated EMI | Compliant with FCC CFR Title 47 Part 15 Class A at 120 & 277 Vac | ||
| Émisi Harmonik Ayeuna | IEC61000-3-2 | For Class C equipment | |
| Voltage Fluktuasi & Flicker | IEC61000-3-3 | ||
| Kekebalan minuhan | ESD (Ngaluarkeun éléktrostatik) | IEC61000-4-2 | 6 kV contact discharge, 8 kV air discharge, level 3 |
| RF Electromagnetic Field Susceptibility | IEC61000-4-3 | 3 V/m, 80 – 1000 MHz, 80% dimodulasi dina jarak 3 méter | |
| Listrik Fast Transient | IEC61000-4-4 | ± 2 kV on AC power port for 1 minute, ±1 kV on signal/control lines | |
| Surge | IEC61000-4-5 | ± 6 kV line to line (differential mode) /± 6 kV line to common mode ground | |
| ANSI/IEEE c62.41.1-2002 & c62.41.2-2002 category A, 2.5 kV ring wave | |||
| Conducted RF Disturbances | IEC61000-4-6 | 3V, 0.15-80 MHz, 80% modulated | |
| Voltage Dips | IEC61000-4-11 | >95% dip, 0.5 period; 30% dip, 25 periods; 95% reduction, 250 periods | |
| Safety & Environmental Approvals | |||
| UL | UL8750 listed Class 2, supplement SF | ||
| cUL | CAN/CSA C22.2 No. 250.13-14 LED equipment for lighting applications | ||
| Kasalametan | |||||
| Hijian | Minimal | has | maksimal | Catetan | |
|
Hi Pot (High Potential) or Diéléktrik voltage-tahan |
Vdc |
2200 |
Tested at the RMS voltage equivalent of 1555 Vac |
||
DIMMING FEATURES
Synchronized Start-up
- The PLS-A series incorporates a synchronized start-up feature.
- When wired into the same dimmer, multiple PLS-A series drivers will dim to the same level and turn on within 20 ms of each other.
Fully Programmable Dimming Curve
- In the PLS-A series, several 0-10V dimming profiles can be selected, such as a logarithmic profile, a non-linear profile with 1% minimum dimming, and a non-linear profile with 10% minimum dimming.
- Furthermore, every point in the non-linear dimming profile can be programmed using the programming software.
CIRI Perlindungan
Input Overcurrent Protection
- The PLS-A series incorporates a primary AC line fuse for input overcurrent protection to prevent damage to the LED driver and meet product safety requirements as outlined in Section 8.
Short Circuit and Overcurrent Protection
- The PLS-A series is protected against short-circuit, such that a short from any output to return shall not result in a fire hazard or shock hazard.
- The driver shall hiccup as a result of a short circuit or over current fault. Removal of the fault will return the driver to within normal operation. The driver shall recover, with no damage, from a short across the output for an indefinite period of time.
Internal Overtemperature Protection
- The PLS-A series is equipped with internal temperature sensor on the primary power train.
- Failure to stay within the convection power rating will result in the power supply reducing the available current (fold back) below the programmed amount.
- The main output current will be restored to the programmed value when the temperature of the built-in temperature sensor cools adequately.
Output Open Load Protection
- When the LED load is removed, the output voltage of the PLS-A series is typically limited to 60 V, to meet Class 2 standard.
OUTPUT POWER PROTECTION
De-Rating At Elevated Temperatures
- The PLS-A series can be operated with cooling air temperatures above 50°C by linearly de-rating the total maximum output power (or current) by 2.5%/°C until internal over-temperature protection activates.
Output Over-Power Protection
- At turn-on with nominal AC input, the PLS-A’ output power shall be clamped to 100%.
DIMMING
- The PLS-A series operate only with 0-10 V dimmers that sink current. They are not designed to operate with 0-10 V control systems that source current, as used in theatrical/entertainment systems. Developed in the 1980’s, the 0-10 V sinking current control method is adopted by the International Electrotechnical Commission (IEC) as part of its IEC Standard 60929 Annex E.
- The method to dim the output current of the driver is done via the +Dim/-Dim Signal pins. The +Dim/-Dim Signal pins respond to a 0 to 10 V signal, delivering 1% to 100% of the output current based on rated current for each model. A pull-up resistor is included internal to the driver. If the +Dim input is > 10 V or open circuited, the output current is programmed to 100% of the rated current.
0-10V dimming is isolated from AC input and DC output for -TPZ models and isolated from AC input for -TZ and TXZ models. - The maximum source current (flowing from the driver to the 0-10 V dimmer) supplied by the +Dim Signal pin is ≤ 0.5 mA. The tolerance of the output current while being dimmed shall be +/-8% typical until down to 1 V.
- In the PLS-A series, several 0-10 V dimming profiles can be selected, such as a logarithmic profile, a non-linear profile with 1% minimum dimming, and a non-linear profile with 10% minimum dimming.
- By default, the non-linear profile with 1% minimum dimming and NO dim-to-off is pre-loaded in the PLS-A series. In this non-linear 0-10 V dimming profile, 10 V to 8 V=100% of the output current, <1 V =1%.

COMPATIBLE 0-10 V DIMMERS
- Lutron, Nova series (part number NFTV)
- Leviton, IllumaTech series (part number IP710-DL)
- Lutron, Diva series (part number DVTV)
PEMROGRAMAN
- The PLS-A series can be programmed by inserting the audio jack of the cable shown here below into the driver and by plugging the USB other end of the cable into a computer. The driver should not be powered on during the programming process.
- When ordering the PLS-A series, please make sure to order a programming cable. The part number for the programming cable is “PROG-JACK-USB”. Additionally, there is an optional programming cradle intended for higher volume use that can be ordered using the part number “PROG-CRADLE”.
- Programming is done by using the ERP LED Driver Configuration Tool (also known as ERP GUI), downloadable through the ERP websitus (https://www.erp-power.com/erp-light-engines/led-light-programming-software/), which enables the user to adjust output current and dimming profile.
- Please note that, for each model, the default output current setting is listed on page 2 of this datasheet.
- Furthermore, when connecting the driver to a computer using the programming cable, you can access the driver’s internal data log and read the following information: SKU, serial number, manufacturing lot code, hours of operation, firmware revision, and power cycles.
- While programming drivers in a lot, the ERP GUI can interface with a label printer, which enables the user to add configuration labels to driver labels in order to highlight programmed output current. Listed below is the equipment needed to print labels.
| Parabot | Nomer Bagian | Dimana meuli |
| Printer | TSC TC210 | barcodefactory.com/tsc/printers/tc210/99-059a001-54lf |
| pita | TSC Prem. Resin, 60mm x 110mm | barcodefactory.com/tsc/35-r060110-23cf |
| Labels | BAR-.81x.28-1-TT | barcodefactory.com/barcodefactory/labels/bar-_81x_28-1-tt |
For more information, please refer to the ERP LED Driver Configuration Tool user’s manual at: (https://www.erp-power.com/erp-light-engines/led-light-programming-software/).
Kabel Pemrograman
- Part number: PROG-JACK-USB

Programming Cradle
- Part number: PROG-CRADLE

PREDICTED LIFETIME VERSUS CASE AND AMBIENT TEMPERATURE
Lifetime is defined by the measurement of the temperatures of all the electrolytic capacitors whose failure would affect light output under the nominal LED load and worst-case AC line voltage. The graphs in Figures 4 and 5 are determined by the electrolytic capacitor with the shortest lifetime, among all electrolytic capacitors. It represents a worst-case scenario in which the LED driver is powered 24 hours/day, 7 days/week. The lifetime of an electrolytic capacitor is measured when any of the following changes in performance are observed:
- Capacitance changes more than 20% of initial value
- Dissipation Factor (tan δ): 150% or less of initial specified value
- Equivalent Series Resistance (ESR): 150% or less of
- Leakage current: less of initial specified value

Catetan
- The ambient temperature Tambient and the differential between Tambient and Tcase mentioned in the above graphs are relevant only as long as both the driver and the light fixture are exposed to the same ambient room temperature.
- If the LED driver is housed in an enclosure or covered by insulation material, then the ambient room temperature is no longer valid. In this situation, please refer only to the case temperature Tcase.
- It should be noted the graph “Lifetime vs. Ambient Temperature” may have an error induced in the final application if the mounting has restricted convection flow around the case. For applications where this is evident, the actual case temperature measured at the Tc point in the application should be used for reliability calculations.
- Users must utilize proper thermal management techniques to ensure proper thermal conductivity between the driver and heat sink. The use of double-sided tape to mount the driver voids the warranty.
EFFICIENCY VERSUS OUTPUT VOLTAGE (100% OF IOUT)

POWER FACTOR VERSUS OUTPUT VOLTAGE (100% OF IOUT)

THD VERSUS OUTPUT VOLTAGE (100% OF IOUT)

DETAIL MEKANIS
MECHANICAL DETAILS “-TZ” MODELS (PLS-A-A20W, PLS-A-A30W, PLS-A-A50W, PLS-AA65W)
- Dimensions: L 257 x W 29 x H 25 mm (L 10.1 x W 1.2 x H 1.0 in.)
- Volume: 190 cm3 (11.6 in3)
- Beurat: 240 g (8.5 oz)
- Packaging: Aluminum case
- I/O Connections: Terminal Blocks
- Ingress Protection: IP20 rated
- Mounting Instructions: The PLS-A driver case must be secured on a flat surface through the two mounting tabs, shown here below in the case outline drawings. The use of double-sided tape voids the warranty.

MECHANICAL DETAILS “-TXZ” MODELS (PLS-A-A20W, PLS-A-A30W, PLS-A-A50W, PLSA- A65W)
- Dimensions: L 257 x W 29 x H 25 mm (L 10.1 x W 1.2 x H 1.0 in.)
- Volume: 190 cm3 (11.6 in3)
- Beurat: 240 g (8.5 oz)
- Packaging: Aluminum case
- I/O Connections: Terminal Blocks
- Ingress Protection: IP20 rated
- Mounting Instructions: The PLS-A driver case must be secured on a flat surface through the two mounting tabs, shown here below in the case outline drawings. The use of double-sided tape voids the warranty.

MECHANICAL DETAILS PLS-A-A85W MODELS
- Dimensions: L 425 x W 29 x H 25 mm (L 16.7 x W 1.2 x H 1.0 in.)
- Volume: 308 cm3 (20.0 in3)
- Beurat: 410 g (14.5 oz)
- Packaging: Aluminum case
- I/O Connections: Terminal Blocks
- Ingress Protection: IP20 rated
- Mounting Instructions: The PLS-A driver case must be secured on a flat surface through the two mounting tabs, shown here below in the case outline drawings. The use of double-sided tape voids the warranty.

LABEL
- The PLS-A-A65W-18-55-TZ is used in figure 19 as an example to illustrate a typical label.

ERP Power, LLC (ERP) reserves the right to make changes without further notice to any products herein. ERP makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does ERP assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in ERP data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. ERP does not convey any license under its patent rights nor the rights of others. ERP products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the ERP product could create a situation where personal injury or death may occur. Should Buyer purchase or use ERP products for any such unintended or unauthorized application, Buyer shall indemnify and hold ERP and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that ERP was negligent regarding the design or manufacture of the part. ERP is an Equal Opportunity/Affirmative Action Employer.
Literatur ieu tunduk kana sadaya undang-undang hak cipta anu berlaku sareng henteu kanggo dijual deui dina cara naon waé.
Riwayat révisi
| titimangsa | Koméntar |
| 06 MAR2025 | • Initial Release |
| 18 MAR2025 | • Updated MCOs |
| 20 MEI2025 | • Added PLS-A-A85W
• Various Grammar Corrections |
| 21 AUG 2025 | • Updated part numbers |
| 03 SEP2025 | • Added note (1) and note (2) in the ORDERING INFORMATION section |
KONTAK
Markas AS
- Telepon: +1-805-517-1300
- Fax: +1-805-517-1411
- 2625 Townsgate Jalan, Suite 106
- Westlake Village, CA 91361, USA
CHINA Operations
- Telepon: +86-756-6266298
- Fax: +86-756-6266299
- No. 8 Pingdong Road 2
- Zhuhai, Guangdong, China 519060
FAQ
Q: Dupi abdi tiasa nganggo supir LED ieu pikeun aplikasi outdoor?
A: The PLS-A Series LED drivers are designed for indoor use only and should not be exposed to outdoor elements.
Q: Naon periode jaminan pikeun produk ieu?
A: The warranty period for the PLS-A Series LED drivers is one year from the date of purchase. Please refer to the warranty terms for more details.
Dokumén / Sumberdaya
![]() |
ERP POWER PLUS LIGHT PLS Series Optional Auxiliary Output [pdf] Instruksi Manual PLS-A20W, PLS-A30W, PLS-A50W, PLS-A65W, PLS-A85W, PLS Series Optional Auxiliary Output, PLS Series, Optional Auxiliary Output, Auxiliary Output, Output |