ESBE CRK210 Controller User Guide

ESBE CRK210 Controller User Guide

ESBE-LOGO

ESBE CRK210 Controller

ESBE-CRK210-Controller-PRODUCT

ESBE Series CRK210 digabungkeun aktuator sareng pengontrol. Kisaran CRK210 nawiskeun kontrol suhu aliran konstan pikeun alat anu digabungkeun sareng fungsi pemanasan & penyejukan. Seri CRK210 dimaksudkeun pikeun dianggo sareng klep Series VRx.

Operasi

  • The CRK210 is a constant temperature controller intended for applications where a constant flow temperature is desired. The controller is integrated with an actuator and is designed to be used with rotating mixing valves series VRx.
  • The Series CRK210 consists of two main components: an actuator and a flow temperature sensor. The primary function of the controller is to maintain a constant set temperature at the sensor location. The series includes a T/T2 (main temperature to alternative temperature) setting, which also controls the opening direction of the actuator. This feature is intended for devices with combined heating and cooling functions set by relay. Additional equipment, such as a clock, may be needed to release the relay if the heating/cooling unit lacks an available control signal. Releasing the relay changes the actuator’s working direction to match the source unit’s mode (heating or cooling). Settings are adjusted via a joystick and displayed on a screen.

Introduction of ESBE Self-Adaptive System

The ESBE Self-Adaptive System manages PI factors (Proportional gain and Integral response) by learning system behaviors and addressing issues previously managed by installers. This system ensures smooth controller operation, eliminates issues related to delays or response times, and delivers high control standards and comfort. This makes the CRK210 Series suitable for any system setup or environment.

INSTALASI

  • Catu daya ku adaptor AC 230 V (lengkep sareng trafo, kabel sareng colokan stop kontak témbok).
  • Sensor suhu aliran hadir sareng kabel 1,5m kalebet (kabel langkung panjang sayogi salaku aksésori). Sensor kudu taliti insulated tina hawa ambient.
  • Hatur nuhun kana panganteur husus antara séri controller CRK210 jeung séri ESBE VRG na VRH, Unit sakabéhna boga stabilitas unik tur precision nalika ngatur.

Parabot Pilihan

  • Art. No. 16200700: ARA801 Auxiliary switch kit
  • Art. No. 17053100: CRA911 Flow temperature sensor, 5m cable
  • Art. No. 17056200: CRA915 UK plug

Valves Pergaulan cocog

  • Runtuyan VRG130
  • Runtuyan VRG230
  • Runtuyan VRG330
  • Runtuyan VRH130
  • Séri 3MG
  • Runtuyan 3G
  • Series 3F DN50

Adaptor Kit
Required adaptor kits for easy fitting onto an ESBE rotary mixing valve series VRx are supplied with each controller. Adaptor kits can also be ordered separately.

  • Art. No. 16000500: ESBE valve series VRG, VRH, G, MG, F
  • Art. No. 16000600: Meibes
  • Art. No. 16000700: Watts
  • Art. No. 16000800: Honeywell Corona
  • Art. No. 16000900: Lovato
  • Art. No. 16001000: PAW
  • Art. No. 16001100: Wita Minimix, Maximix

KONTROLLER

ESBE-CRK210-Controller- (2)

Seni. Henteu Rujukan Voltage [VAC] Temp. rentang Torsi [Nm] Beurat [kg] Catetan Ngaganti
12729100 CRK211 230 5-95°C 6 0.5 12725100

Technical Data Details

  • Ambient temperature: max. +55°C, min. -5°C
  • Tipe sénsor: NTC
  • Temperature range: Flow temperature sensor +5 to +95°C
  • Enclosure rating, Actuator unit: IP41
  • Kelas panyalindungan: II
  • Power supply, Actuator unit: 230 ± 10% V AC, 50 Hz
  • Power consumption (230 V AC): 10 VA
  • Torque (Actuator): 6 Nm
  • Running time at max. speed (Actuator): 30s
  • ErP Temperature control class: N/A
  • Energy efficiency contribution: N/A

Complies with LVD 2014/35/EU, EMC 2014/30/EU, RoHS 2011/65/EU

Pamasangan EXAMPLE

ESBE-CRK210-Controller- (1)

Suhu aliran konstan nuju ka sirkuit pemanasan
CRK210 ngadalikeun sarta ngamankeun suhu aliran set. Controller disambungkeun ka alat jeung fungsi pemanasan sarta cooling gabungan. Sambunganna dilakukeun ku relay, anu nalika dileupaskeun bakal ngarobih arah muka CRK210. Fitur ieu ngamungkinkeun CRK210 pikeun nyaluyukeun prinsip kerja antara pemanasan atanapi cooling mode kerja alat pemanasan / cooling.

Aplikasi anu dipidangkeun ngan ukur examples pamakéan produk! Sateuacan nganggo produk dina aplikasi naon waé, peraturan régional sareng nasional kedah dipariksa.

Dokumén / Sumberdaya

PDF thumbnailCRK210 Controller
User Guide · CRK210, CRK210 Controller, CRK210, Controller

Rujukan

Tanya patarosan

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Tanya patarosan

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.