LUTRON MS-HS3 Kalembaban Sénsor Pindah

spésifikasi
- Modél: MS-HS3
- produk: Humidity Sensor Switch
- Input kakuatan: 120 V~ 50 / 60 Hz
- Beban maksimum: 3 A
- Aplikasi: English Fan
Bubuka
Saklar sensor kalembaban ngadalikeun knalpot sareng kipas angin pikeun ngaleungitkeun Uap dina rohangan nalika tingkat kalembaban ngaleuwihan ambang. Saklar sensor kalembaban anu idéal pikeun kamar mandi sabab bisa ngadeteksi kanaékan gancang dina asor tina pancuran atawa mandi pikeun ngurangan kapang jeung mildew. Éta ogé bakal ngadeteksi paningkatan bertahap dina kalembaban di kamar mandi ogé kamar utiliti, ruangan bawah tanah, sareng rohangan sanés.
Catetan penting
- PERHATOSAN: Pikeun ngirangan résiko overheating sareng kamungkinan ruksakna alat-alat sanés, ULAH dianggo pikeun ngendalikeun wadah.
- Masang saluyu sareng sadaya kode listrik nasional sareng lokal.
- A neutral or ground connection is required for the product to function. When a neutral connection is available, remove the green sleeve and connect to the neutral. If a neutral is not available, connect the green-sleeved wire to ground only in retrofit and replacement applications. If neither wire is present, consult a licensed electrician.
- For indoor / dry location use only. Operate between 32 °F and 104 °F (0 °C and 40 °C).
- Beresih ku hipu damp lawon hungkul. ULAH ngagunakeun beberesih kimia naon waé.
- Ulah ngaleuwihan dua puluh (20) alat dina sirkuit cabang tunggal.
- Device makes an audible click when turning on / off. This is normal functionality.
- Do not use for ceiling paddle fans.
- For supply connections use 18 AWG (1.0 mm2) or larger wires suitable for at least 167 °F (75 °C).
WARNING: ENTRAPMENT HAZARD.
To avoid the risk of entrapment, serious injury, or death, these controls must not be used to control equipment that is not visible from every control location or that could create hazardous situations if operated accidentally or through malfunction (for example, Gerbang motorized, panto garasi, panto industri, oven microwave, hampang pemanasan, fireplaces, pamanas spasi, jsb). Tanggung jawab pamasang pikeun mastikeun yén kadali ieu ngan ukur nyambung ka beban sareng jinis alat anu cocog sareng alat sapertos kitu katingali ti unggal lokasi kontrol. Gagal pikeun ngalakukeunana tiasa ngakibatkeun tatu serius atanapi maot.
Pareuman kakuatan dina pemutus sirkuit
PERHATOSAN: BAHAYA SHOCK.
Bisa ngakibatkeun tatu serius atanapi maot. Pareuman kakuatan dina circuit breaker atanapi sekering sateuacan dipasang.
Ensure a neutral or ground connection is present
Look for a bundle of white neutral wires coming out of the electrical box.
- A. When a neutral is present, remove the green sleeve and connect the white wire to neutral from the electrical box. Connect the bare wire from the device to the ground wire from the electrical box.
- B. If no neutral is present, connect the bare and green-sleeved wire from the device to the ground wire from the electrical box (can only be used in retrofit and replacement applications when neutral is not available).
- C. If neither wire is present, consult an electrician. This device will not function if it is not connected to neutral or ground.
Remove the existing device and connect the humidity sensor switch
Catetan: The humidity sensor switch is for single-pole locations only. Not for use in 3-way or multi-location circuits.
- A. Mun nétral aya dina kotak listrik: Cabut leungeun baju héjo, sambungkeun kawat bodas mun nétral.

Catetan:
- Wire colors in the electrical box may vary.
- The black wires coming out of the humidity sensor switch are interchangeable.
If neutral IS NOT present in the electrical box: Connect the green-sleeved wire to ground. 
Catetan: The black wires coming out of the humidity sensor switch are interchangeable.
Mount the switch using the provided screws 
Hurungkeun kakuatan dina circuit breaker
Once the power has been restored the status LED will blink until the device is fully powered up, which may take up to 20 seconds. Pressing the main toggle button during this time will not change the load state and the LED will continue to blink to indicate the powering up is still in progress. After power has been restored and the device has fully powered up, the main toggle button can be used to change the state of the load and to test the installation. Note: Humidity sensing will not be operational until the timeout has expired after a button press to turn off the fan. The default timeout is 30 minutes.

Additional modes and settings
Setélan pabrik standar geus dioptimalkeun pikeun minuhan ekspektasi paling konsumén pikeun mandi baku sarta damp spasi (misalna, kamar utiliti jeung basements). Tapi, switch sensor kalembaban boga sababaraha setelan adjustable nu bisa dipaké pikeun ngarobah operasi pikeun preferensi pamaké atawa lamun perlu pikeun alamat masalah husus pikeun nampung konfigurasi spasi non-standar. Hawa Daur Mode Mode ieu dipaké pikeun ngiderkeun bulukan, stagnant air in spaces such as basements with poor ventilation. The fan will turn on every hour and run for the duration determined by the timeout setting. To enable Air Cycle Mode, go to www.lutron.com/MS-HS3/air_cycle
Pamasangan parantos réngsé
Lutron recommends adding the support QR code label (provided in box) to the back of the wallplate prior to fully installing it over the humidity sensor switch. If changes are needed after living with the humidity sensor switch for a few days, adjustments can be made by scanning the QR code or by going to www.lutron.com/MS-HS3 to get detailed instructions on how to make changes to the settings by using Advanced Programming Mode (APM).
Operasi
Operasi Umum
The humidity sensor switch measures humidity levels in the space and uses advanced signal processing to determine when to activate the fan. The default operating mode will detect shower activity and / or high humidity levels, at which point the controlled fan will turn on. The fan will then run until the user-selectable timeout has expired (the default setting is 30 minutes). When the fan is running, the white status LED will be bright. Once the timeout has expired, the white status LED will transition to “dim”. For most bathrooms, the fan will turn on during the shower or slightly after the shower has ended and the user has opened the shower enclosure. Typical propagation of humid air will fill the room starting at the ceiling and then move down the walls. This means that it is not uncommon for the mirror to begin fogging before the control senses that the humidity has changed and turns on the fan.
Operasi
Catetan: The ability of the humidity sensor switch to detect changes in humidity levels and how quickly the fan turns on can be impacted by many factors. Spaces with high ceilings, open floorplans, glass shower doors with small openings, or significant ventilation will delay the movement of humidity towards the control and delay when the fan turns on.
- The default timeout period is 30 minutes. This is a global timeout that applies to any operation where timeout period is referenced. Timeouts and humidity sensing modes are programmable. For more information, go to www.lutron.com/MS-HS3

Catetan:
- The status LED will cycle between 2 seconds bright and a 0.5 seconds dim.
- Pressing the main toggle button once will return the unit to normal operation.
Catetan
- The status LED will cycle between 2 seconds dim and a 0.5 seconds bright.
- Pressing the main toggle button once will return the unit to normal operation.
Pamérésan masalah
Pikeun pangalaman pangsaena sareng ngartos sapinuhna operasi switch sensor kalembaban di rohangan unik anjeun, Lutron nyarankeun yén anjeun cicing sareng alat pikeun sababaraha dinten nganggo setélan standar sateuacan ngadamel panyesuaian.
- Test the fan operation by manually pressing the toggle button. If the fan does not turn on, turn offthe power at the breaker and check the wiring. If the status LED turns bright when the button is pressed but the fan does not turn on, the fan may be faulty and may need to be replaced.
Catetan: Humidity sensing will not be operational until the timeout has expired after a button press to turn off the fan. The default timeout is 30 minutes. - If the device is not operating as expected, please scan the QR code label on the humidity sensor switch or go to www.lutron.com/MS-HS3 to learn about helpful hints and tips to optimize the sensor switch for your space.
- If additional help is needed, please go to the Need Help section at www.lutron.com/MS-HS3
FAQs
Q: Naha switch sensor kalembaban tiasa dianggo dina sirkuit multi-lokasi?
A: No, the humidity sensor switch is designed for single-pole locations only and should not be used in 3-way or multi-location circuits.
Q: Naon anu kuring kedah laksanakeun upami kuring henteu gaduh sambungan nétral atanapi taneuh dina kotak listrik kuring?
A: If no neutral is present, connect the green-sleeved wire to ground. If neither wire is present, it is recommended to consult an electrician for proper installation.
Q: Kumaha carana abdi tiasa nguji lamun switch sensor kalembaban anu fungsina leres?
A: After installation, restore power and observe the LED status indicator. Press the main toggle button to test changing the load state. Allow the default timeout of 30 minutes after turning off the fan to activate humidity sensing.