spésifikasi

  • Series: cMT-G02X
  • Luhurna: 3,000 m
  • Peunteun IP: IP 20
  • Kalembaban Relatif: 10% - 90% (non-condensing)
  • Cleaning: Clean with dry cloths, avoid liquid or spray detergents
  • Spésifikasi batré: Tipe CR1220, Dipeunteun 3V

Instalasi jeung ngamimitian Guide

This document covers the installation of cMT-G02X Series HMI, for the detailed specifications and operation, please refer to Datasheet, Brochure and EasyBuilder Pro User Manual. Please read all warnings, precautions, and instructions on the device carefully before use.

Lingkungan Pasang:

 

Lingkungan Listrik

Produk HMI parantos diuji pikeun saluyu sareng syarat CE Éropa. Ieu ngandung harti yén sirkuit dirancang pikeun nolak épék sora listrik. Ieu teu ngajamin kekebalan noise dina kasus parna. Rute kawat sareng grounding anu leres bakal ngajamin operasi anu leres.
 

 

 

Pertimbangan Lingkungan

  1. Pastikeun yén unit dipasang leres sareng yén wates operasi diturutan. Hindarkeun masang unit dina lingkungan dimana aya geter mékanis atanapi guncangan anu parah.
  2. Entong ngajalankeun unit di daérah anu bahaya ngabeledug kusabab gas, uap atanapi lebu anu gampang kaduruk.
  3. Entong masang unit dimana aya gas asam, sapertos SO2.
  4. Alat ieu kudu dipasang dina posisi nangtung sarta pikeun pamakéan dina dipager permukaan datar.
  5. Pikeun dianggo dina Polusi Gelar 2 Lingkungan sareng lokasi garing.
  6. Kalembaban relatif: 10% ~ 90% (non-condensing)
Luhurna 3,000 m
rating IP IP 20
beberesih

Pertimbangan

Bersihkeun alat nganggo kaen garing. Ulah make detergents cair atawa semprot pikeun

beberesih.

 

Awas

Karusakan panyalindungan upami dianggo dina cara anu henteu ditangtukeun ku produsén.

Ngabongkar Unit

  • Buka bungkusan sareng pariksa pangiriman. Lamun karuksakan kapanggih, wartosan supplier nu.
  • CATETAN: Teundeun panel operator dina permukaan stabil salila instalasi. Muterkeun atawa ngantepna ragrag bisa ngabalukarkeun karuksakan.

pakét ngawengku:

  1. Parentah Instalasi, 2-sided A4 * 1
  2. cMT-G02X *1
  3. Panyambung Daya *1
  4. Antenna 2dBi *1

Parentah instalasi

  • Pamasangan rel: DIN rel 35mm
  • Panel dipasang: Use two M4 or #8 panhead screws, mounting hole size is 4.6mm
  • Plan for adequate space around the unit and inside the enclosure, for ventilation and cables. Consider the heat from other devices inside the enclosure. The ambient temperature around the unit must be -20 ~ 55°C.WEINTEK-CMT-G02X-Series-Data-Gateway-image (1)

Sambungan kakuatan

Spésifikasi Panyambung Daya

  • Kawat AWG: 24~12
  • Wiring Konduktor Suhu Minimum: 75°C
  • Torsi Screw: 4.5 lbf-in (maks.)
  • Kalakuan tambaga wungkul.

WEINTEK-CMT-G02X-Series-Data-Gateway-image (2)

CATETAN: Sambungkeun garis DC positif kana terminal '+' jeung taneuh DC ka terminal '-'.

Setélan Sistim

Sambungkeun cMT-G02X ka router nganggo kabel Ethernet RJ-45. Ngajalankeun EasyBuilder Pro on PC nu, turutan bagian 6 parentah pikeun aksés ka jandela download, sarta manggihan cMT-G02X pikeun ménta alamat IP na. Lebetkeun alamat IP ieu dina a web browser pikeun ngakses kaca setelan sistem, dimana sandi standar "111111" bisa dipaké pikeun asup jeung ngonpigurasikeun alat.

WEINTEK-CMT-G02X-Series-Data-Gateway-image (3)November 17, 2025 32 KB 743 by 218 pixels Edit Image Delete permanently

EasyBuilder Pro Setélan Software

  • Ngajalankeun software EasyBuilder Pro, pilih proyék Anjeun file, press F7 to open the download dialog box: Select Ethernet > IP tab > Enter your HMI IP > Click Download to download this project
    file ka HMI.
  • Mémori lampu kilat gaduh umur tulis anu kawates, sareng sering nyerat data (contona, Log Acara, Data Sampling) bisa ngagancangkeun degradasi. Pertimbangkeun frékuénsi nulis sareng manajemén umur hirup dina desain sistem pikeun nyegah leungitna data. Tingal "3.2.1. Manjangkeun Umur Flash Mémori" dina Buku Panduan Pamaké Kaamanan Produk pikeun pituduh.
  • (Punten tingal Manual Pamaké EasyBuilder Pro kanggo detil operasi parangkat lunak.)

Sambungan Komunikasi

CATETAN:

  1. COM2 jeung COM3 [RS485] 2W ngarojong MPI 187.5K, punten nganggo hiji-hiji.
  2. Paké # 4-40 UNC screws pikeun instalasi konektor D-SUB.
  • 9 Pin, Lalaki, D-sub
  • COM1 [RS232]
  • COM2 [RS485]
  • COM3 [RS485] WEINTEK-CMT-G02X-Series-Data-Gateway-image (4)
PIN# COM1 [RS-232]

2W

COM2 [RS-485] COM3 [RS-485]

2W

2W 4W
1 Data +
2 RxD
3 TxD
4 Data-
5 GND
6 Data + Rx +
7 Data- Rx-
8 Tx +
9 Tx-

DIP SW Setélan WEINTEK-CMT-G02X-Series-Data-Gateway-image (4)

SW1 SW2 Modus
Pareum Pareum Modeu Normal
ON Pareum Mulangkeun Setélan IP Ethernet
Pareum ON Boot Loader Mode
ON ON Mulangkeun Default Pabrik

  • Turn ON SW1 and power the unit again, the IP setting is restored to default:
    • Ethernet 1: DHCP
    • Wifi: DHCP
  • When restoring factory defaults, all projects and data stored in the unit will be cleared.

Ngagantian batré

Parentah Kasalametan

PERHATOSAN

CATETAN: Pastikeun yén sadaya standar listrik lokal sareng nasional dicumponan nalika masang unit. Taroskeun otoritas lokal anjeun pikeun nangtukeun kodeu mana anu berlaku.

Kakuatan
Anggo kaluaran kakuatan anu nyumponan SELV (Safety Extra-Low Voltage) syarat. Unit bisa Powered by kakuatan DC wungkul, voltagrentang e: 24 ± 20%, cocog sareng paling sistem controller DC. Sirkuit udar listrik di jero unit dilaksanakeun ku catu daya switching. Puncak arus ngamimitian tiasa saluhur 500mA.

Syarat fusing
Upami tampilan henteu hurung dina 5 detik saatos kakuatan, cabut kakuatan. A sekering resettable bakal ngajaga ngalawan faults overcurrent dina sirkuit DC jeung reset bakal lumangsung sanggeus hiji periode waktu. Pariksa wiring pikeun sambungan ditangtoskeun jeung cobaan deui kakuatan up.

Luhur Voltage

  • Sekering anu tiasa direset bakal nyegah karusakan pikeun kaayaan arus langkung tapi henteu dijamin.
  • DC voltagSumber e kedah nyayogikeun isolasi anu pas tina kakuatan AC utama sareng bahaya anu sami.

Eureun Darurat
STOP DARURAT kabel Hard kudu dipasang dina sistem naon waé anu nganggo HMI pikeun matuh Rekomendasi Kasalametan ICS.

Pasokan Voltage kaayaan
Entong ngawasa unit sareng beban DC induktif, atanapi sirkuit input ka controller, kalayan catu daya anu sami. Catetan: Kaluaran 24 VDC ti sababaraha pangendali tiasa henteu gaduh arus anu cukup pikeun ngawasa unit.

Kawat Routing

  • Panjang kawat kakuatan kudu diminimalkeun (Max: 500m shielded, 300m unshielded).
  • Punten nganggo kabel pasangan twisted pikeun kawat listrik sareng kawat sinyal sareng saluyu sareng impedansi anu cocog.
  • Upami wiring kedah kakeunaan kilat atanapi surge, paké alat-alat suprési surge anu pas.
  • Tetep AC, énergi tinggi, sarta gancang ngaganti kabel kakuatan DC dipisahkeun tina kawat sinyal.
  • Tambahkeun résistor jeung kapasitor dina sambungan paralel antara catu daya DC ungrounded jeung taneuh pigura. Ieu nyadiakeun jalur pikeun dissipation statik sarta frékuénsi luhur. Nilai anu biasa dianggo nyaéta 1M Ohm sareng 4700pF.

BAHAYA

Pertimbangan Hardware

  • Desainer sistem kedah sadar yén alat-alat dina sistem Controller tiasa gagal sahingga nyiptakeun kaayaan anu teu aman. Saterusna, gangguan listrik dina panganteur operator bisa ngakibatkeun alat ngamimitian-up, nu bisa ngakibatkeun karuksakan harta jeung / atawa tatu fisik ka operator.
  • Upami anjeun nganggo sistem kontrol anu tiasa diprogram anu meryogikeun operator, perhatikeun yén poténsi bahya kaamanan ieu aya sareng nyandak pancegahan anu pas. Sanaos léngkah-léngkah desain khusus gumantung kana aplikasi khusus anjeun, pancegahan di handap ieu umumna dilarapkeun ka pamasangan alat kontrol anu tiasa diprogram kaayaan padet, sareng saluyu sareng pedoman pikeun pamasangan Controllers anu disarankeun dina Standar Kontrol NEMA ICS 3-304.

Pemrograman Pertimbangan
Pikeun saluyu sareng Rekomendasi Kasalametan ICS, cék kedah ditempatkeun dina pangontrol pikeun mastikeun yén sadaya register anu tiasa ditulis anu ngatur bagian kritis pabrik atanapi mesin gaduh pamariksaan wates anu diwangun dina program, kalayan prosedur pareum anu aman di luar wates pikeun mastikeun kasalametan. tina tanaga.

GMECMG2X0_cMT-G02X_Pasang_20250901

Garansi kawates

  • Produk ieu kawates warranted ngalawan defects dina rarancang jeung pabrik.
  • Produk cacad anu kabuktian bakal dibenerkeun atanapi diganti, dina kawijaksanaan Weintek.
  • Garansi ieu moal nutupan produk naon waé
    • Kaluar tina masa garansi nyaéta 12 bulan ti bulan manufaktur produk HMI.
    • Ruksakna disababkeun ku Force Majeure, kacilakaan, lalawora, instalasi bener atawa nyalahgunakeun.
    • Produk parantos dilereskeun atanapi dipisahkeun ku teknisi anu henteu sah.
    • Produk anu tanda idéntifikasina parantos dipiceun atanapi ruksak.

FAQ

How do I access the system settings page?

Sambungkeun cMT-G02X ka router nganggo kabel Ethernet RJ-45. Ngajalankeun EasyBuilder Pro on PC nu, turutan bagian 6 parentah pikeun aksés ka jandela download, sarta manggihan cMT-G02X pikeun ménta alamat IP na. Lebetkeun alamat IP ieu dina a web browser to access the system settings page where the default password 111111 can be used to log in and configure the device.

What should I do if I need to restore factory defaults?

Turn ON SW1 and power the unit again to restore the IP settings to default. Note that when restoring factory defaults, all projects and data stored in the unit will be cleared.

Dokumén / Sumberdaya

WEINTEK CMT-G02X Series Data Gateway [pdf] Pituduh instalasi
CMT-G02X Series, CMT-G02X Series Data Gateway, Data Gateway, Gateway

Rujukan

Ninggalkeun komentar

alamat surélék anjeun moal diterbitkeun. Widang diperlukeun ditandaan *